Section H.
В
Troubleshooting
Belarus – 510/512 Operating manual
117
Table H-1, continued
TROUBLE, EXTERNAL MANIFESTATION
REMEDY
HYDRAULIC LIFT LINKAGE
Hinge does not lift or its lifting capacity sharply re-
duced.
1. Low oil level in tank — add oil to level.
2. Air sucked into the suction line of the pump —
eliminate air suction (oil foaming).
3. Sticking of distributor relief valve (take out valve
parts, rinse and install to place).
Lifting capacity drops when oil warms up. When oil
cools down, lifting capacity restores.
Worn or broken oil pump — replace pump.
Hydraulic system oil too hot
1. Insufficient oil in hydraulic system housing (add
oil to the mark “
П
”).
2. The distributor arm is in the lifting position (return
the arm to the neutral position, find and eliminate
the cause of jamming).
3. Pump lost its capacity (replace pump).
Spontaneous lowering of implement
1. Oil leakage over sealings of cylinder piston (re-
place sealing).
2. Leaky pilot-operated check valve of distributor
(rinse or replace valve).