Modbus
address
Contents
Description / explanation
Data type
3206
Error6 Flag
Voltage supply drop during discharge
1 = Error active
0 = Error inactive
u16
3.4.3.2
Read Device Identification (0x2B / 0x0E)
The advanced function (MEI Type) Read Device Identification (0x2B / 0x0E), can be used to read out the following
device-specific data.
Object
ID
Item name
(Modbus
specification)
Description / explanation Examples
Format
0x00
VendorName
Manufacturer
BEKO
TECHNOLOGIES
ASCII
0x01
ProductCode
BEKO
material number circuit
board
4023034
ASCII
0x02
MajorMinorRevision
Software version numbers*
APP V2.3.0 BBS V3.4.0 CFG V1.0.0
ASCII
0x03
VendorUrl
BEKO
website
http://www.beko-technologies.
com
ASCII
0x04
ProductName
BEKO
product name
BEKOMAT
ASCII
0x05
ModelName
BEKO
circuit board designation
KA2C OL11 2044 ELV P i4.0
ASCII
0x06
UserApplicationName
BEKO
serial number circuit
board
1912720040
ASCII
0x80
n.a.
Production: Circuit board test
date
03/01/2018/14:53:16/01/01/01
ASCII
0x81
n.a.
Production: Circuit board
adjustment date
04/02/2018/08:25:44/01/01/01
ASCII
0x82
n.a.
Production: Circuit board
calibration date
04/02/2018/08:25:44/01/01/01
ASCII
0x83
n.a.
Production: free
04/02/2018/08:25:44/01/01/01
ASCII
0x85
n.a.
BEKO
material number
BEKOMAT
®
0004046022
ASCII
0x86
n.a.
BEKO
serial number
BEKOMAT
®
0014345535
ASCII
0x87
n.a.
Customer material number,
optional
--
ASCII
* Legend:
APP = application
BBS =
BEKO
basic software
CFG = Configuration
BEKOMAT
®
16i CO
Original installation and operation manual