11.  Consumables, accessories and spare parts ................................................................................ 59

11.1  Order information ................................................................................................................ 59
11.2 Accessories ........................................................................................................................... 59
11.3  Spare parts............................................................................................................................ 60

12. Decommissioning ....................................................................................................................... 65

12.1  Warning notices ................................................................................................................... 65
12.2  Decommissioning work ....................................................................................................... 66

13. Dismantling ................................................................................................................................. 67

13.1  Warning notices ................................................................................................................... 67
13.2  Dismantling work ................................................................................................................. 68

13.2.1  Concluding work ...........................................................................................................................69

14. Disposal ....................................................................................................................................... 70

14.1  Warning notices ................................................................................................................... 70
14.2  Disposal of operating and auxiliary materials .................................................................... 71

15.  Troubleshooting and fault repair / FAQ .................................................................................... 72

16. Appendices .................................................................................................................................. 73

16.1  Approval certificates and declarations of conformity

 ........................................................ 73

16.2  Declaration of Conformity ................................................................................................... 74

BEKOMAT

®

 16i CO

Original installation and operation manual

4 | 76

Содержание BEKOMAT 16i CO

Страница 1: ...EN BEKOMAT 16i CO 01 4287 Original installation and operation manual BM16iCO ...

Страница 2: ... and storage 11 2 5 5 Installation 11 2 5 6 Maintenance 12 2 5 7 Handling hazardous substances 12 2 5 8 Use of spare parts accessories or materials 13 2 6 Warning notices 13 3 Product information 14 3 1 Exploded view BEKOMAT 16i CO 14 3 2 Product overview 16 3 3 Function description 17 3 4 Modbus function 18 3 4 1 Default interface parameters 18 3 4 2 Byte sequence 18 3 4 3 Implemented functions 1...

Страница 3: ...ly work 33 7 Electrical installation 36 7 1 Warning notices 36 7 2 Connection work 37 7 2 1 Single device connection 38 7 2 2 Connecting multiple Modbus devices series connection 40 8 Commissioning 42 8 1 Warning notices 42 8 2 Commissioning work 43 9 Operation 44 9 1 Warning notices 44 9 2 Operating states 45 10 Maintenance 47 10 1 Warning notices 47 10 2 Maintenance schedule 48 10 3 Maintenance ...

Страница 4: ...6 13 Dismantling 67 13 1 Warning notices 67 13 2 Dismantling work 68 13 2 1 Concluding work 69 14 Disposal 70 14 1 Warning notices 70 14 2 Disposal of operating and auxiliary materials 71 15 Troubleshooting and fault repair FAQ 72 16 Appendices 73 16 1 Approval certificates and declarations of conformity 73 16 2 Declaration of Conformity 74 BEKOMAT 16i CO Original installation and operation manual...

Страница 5: ...al drawings diagrams and other representations are protected by the copyright of the manufacturer The distribution as well as the duplication of this document the exploitation and the communication of its contents are prohibited unless expressly authorised Publication date Revision Version Reason for amendment Scope of amendment 18 May 2021 01 00 Editorial revision Editorial changes 30 June 2021 0...

Страница 6: ...ater exposure that can occur The splash water must be free of corrosive components Only use the product and accessories in areas which are free of toxic and corrosive chemicals and gases Only use the product and accessories within the piping system designed for the technical data with appropriate connections pipe diameters and assembly clearances Only use the product and accessories outside potent...

Страница 7: ...ccessories which are not listed here the manufacturer must be informed immediately 2 2 Responsibility of the operating company The responsible operating company must ensure the following to prevent accidents incidents and adverse effects on the environment Before all actions check to ensure that the manual available does in fact belong to the product The product and the accessories are used servic...

Страница 8: ...pment and plants are people who due to their training professional experience and qualification possess all the necessary capabilities to safely execute actions and instruct all actions related to pressurised fluids and systems to independently foresee potential hazardous situations and implement appropriate measures to avert any danger The capabilities include in particular experience in handling...

Страница 9: ...um operation Symbol Description explanation General warning symbol danger warning caution Warning pressurised system Warning electric voltage Observe the installation and operation manual General note Wear safety footwear Use protective gloves cut proof and liquid resistant Wear safety goggles with side shields i General information Original installation and operation manual BEKOMAT 16i CO 9 76 ...

Страница 10: ...nd accessories may lead to serious personal injuries or death To guarantee safe operation of the product and accessories observe the following points Use suitable protective equipment during all work on the product or accessories Adhere to the limits and operating parameters specified on the type plate and in the manual Adhere to the assembly conditions and ambient conditions Check whether the per...

Страница 11: ...le packaging the product and accessories carefully Transport and handle the packaged product and accessories according to the markings on the packaging note lifting gear attachment points the centre of gravity and alignment e g keep vertical do not throw etc Only use proper means of transport and lifting equipment that is in proper working order Always adhere to the permissible transport and stora...

Страница 12: ...air work Prevent contamination from entering the opened product or accessories Store the disassembled components and accessories directly in a safe place After completing maintenance and repair work remove all the tools and cleaning media used as well as all parts that are no longer needed from the work area Only dispose of the product and accessories when cleaned and freed of any media residue Di...

Страница 13: ...notices Warning notices warn against dangers when handling the product and accessories In order to prevent accidents personal injury and damage to property as well as impairments during operation it is essential to adhere to the warning notices Structural set up SIGNAL WORD Type and source of danger Symbol Possible consequences if the danger is ignored Measure to prevent the danger Signal words DA...

Страница 14: ...le clamp 40 Housing upper part 13 Cover mounting element 41 Screw M3 x 6 14 Bottom cover 42 Plug 15 Sealing ring PG7 43 O ring 27 x 2 mm 16 Pressure ring PG7 44 Sensor tube 17 Pressure screw PG7 45 O ring 34 59 x 2 62 mm 18 Housing 46 O ring 104 x 3 mm 19 Flat gasket 21 5 x 26 mm 47 O ring 5 5 x 1 5 mm 20 Locking screw G1 2 48 O ring 5 5 x 1 5 mm 21 Plug 49 Fixing screw 22 Rising pipe 50 Solenoid ...

Страница 15: ... 51 50 49 48 47 46 44 40 42 45 43 55 56 1 4 5 6 3 7 8 9 11 12 13 14 10 15 16 17 18 19 20 27 26 25 23 22 21 24 28 34 33 32 31 30 29 35 39 41 36 37 38 Original installation and operation manual BEKOMAT 16i CO 15 76 ...

Страница 16: ...tion explanation Item Description explanation A Control panel E Valve unit B Right cable gland F Condensate inlet C Left cable gland G Connection for venting line D Condensate discharge BEKOMAT 16i CO Original installation and operation manual 16 76 ...

Страница 17: ...ve X1 activates and the area above the membrane 23 is depressurised The membrane 23 lifts off the valve seat and the excess pressure in the housing 18 presses the condensate into the condensate discharge D 44 F X1 23 D When the sensor in the sensor tube 44 is no longer covered by condensate the controller of the pilot valve X1 activates and pressure builds up above the membrane 23 The membrane 23 ...

Страница 18: ...ble via Modbus 10 seconds after start up with the following interface parameters Value Parameter Baud rate 19200 Data bits 8 Stop bits 1 Parity even Client address 247 3 4 2 Byte sequence Data type Modbus register Division float 2 Register ABCD u32 2 Register ABCD u16 1 Register AB u8 1 Register A u8 B 3 4 3 Implemented functions The following Modbus functions are supported 1 Read Input Registers ...

Страница 19: ...LED 100 1 LED 50 2 u16 1760 Main Button State Status TEST button On 1 Off 0 u16 3103 Remaining Time Hi Word Remaining service time float 3104 Remaining Time Lo Word 3105 Remaining Counts Hi Word Remaining switching cycles float 3106 Remaining Counts Lo Word 3200 Error Flags All Error Flags Bit 1 Error1 Flag Bit 2 Error2 Flag Bit 3 Error3 Flag Bit 4 Error4 Flag Bit 5 Error5 Flag Bit 6 Error6 Flag u...

Страница 20: ...e http www beko technologies com ASCII 0x04 ProductName BEKO product name BEKOMAT ASCII 0x05 ModelName BEKO circuit board designation KA2C OL11 2044 ELV P i4 0 ASCII 0x06 UserApplicationName BEKO serial number circuit board 1912720040 ASCII 0x80 n a Production Circuit board test date 03 01 2018 14 53 16 01 01 01 ASCII 0x81 n a Production Circuit board adjustment date 04 02 2018 08 25 44 01 01 01 A...

Страница 21: ...owByte Modbus Client address 1 246 Example value 0x070A decimal 1802 For interface parameters see table Index 0x07 decimal 7 Client address 0x0A decimal 10 3 To save the settings write the value 0xBA5E decimal 47710 to the Holding Register 0x139C decimal 5020 4 Switch the product off and switch it back on again 0 The changes will go into effect approx 10 seconds after the restart Parameter HighByt...

Страница 22: ...intenance Restart device 0x1773 6003 0x8E40 Restart the device 1 Write the value 0xBEEF decimal 48879 to the Key Register 0x1392 decimal 5010 0 Write access and control command function are released for 1 minute 2 Select the control command from the control command table and write it to the respective Control Holding Register Example Reset the time until the next maintenance Register Value Control...

Страница 23: ... 7 D 41468 NEUSS Made in Germany 12345678 IP 65 TYPE13 4046928 12345678 0 8 16 bar g 12 230 psi g 1 60 C 34 140 F 24 VDC 10 8W BM16i Example illustration Item Description explanation 1 Product name 2 Operating pressure 3 Operating temperature 4 Material number 5 Operating voltage 6 Manufacturer 7 IP degree of protection 8 Housing class 9 Serial number For more information see 2 4 Explanation of th...

Страница 24: ...elivery of the BEKOMAT Illustration Description explanation BEKOMAT 16i CO DE BEKOMAT 16i CO 01 4254 Original Installations und Betriebsanleitung BM16iCO Original installation and operation manual BEKOMAT 16i CO Original installation and operation manual 24 76 ...

Страница 25: ...5 mm 1 2 in Connection condensate discharge 1 x G1 2 internal Media Condensate oil contaminated or oil free Empty weight 5 90 kg 13 lbs Operating voltage 24 VDC 10 see type plate Power consumption P 8 0 VA W Degree of protection IP65 Housing class UL50E TYPE 13 Overvoltage category IEC 61010 1 III Degree of pollution IEC 61010 1 3 Recommended cable diameter 5 10 mm 0 23 0 33 in Recommended wire cr...

Страница 26: ...ials BEKOMAT 16i CO Housing Aluminium hardcoated Membrane FKM 4 4 Dimensions BEKOMAT 16i CO mm inch 280 11 02 260 10 24 SW36 1 42 145 5 71 135 5 32 130 5 12 130 5 12 49 1 93 180 7 09 280 11 02 30 1 18 G1 2 NPT 1 2 M6 G1 2 NPT 1 2 G3 4 NPT 3 4 G1 NPT 1 40 1 58 20 0 79 10 0 40 BEKOMAT 16i CO Original installation and operation manual 26 76 ...

Страница 27: ...Nm 0 5 Nm 1 11 ft lb 0 37 ft lb Z2 Screw solenoid valve connector 1 0 Nm 0 2 Nm 0 74 ft lb 0 15 ft lb Z3 Screws membrane cap valve unit 2 5 Nm 0 5 Nm 1 84 ft lb 0 37 ft lb Z4 Nuts housing 20 Nm 5 Nm 14 75 ft lb 3 69 ft lb Z5 Screws top cover 0 5 Nm 0 30 Nm 0 37 ft lb 0 22 ft lb Original installation and operation manual BEKOMAT 16i CO 27 76 ...

Страница 28: ...e above the top cover at the place of installation so that the LEDs are visible and the TEST button can be pressed 4 7 Terminal diagram power control board Illustration ON OFF ON OFF GND 0V RS485 B RS485 A 24 V GND 0V RS485 B RS485 A 24 V Modbus termination BEKOMAT 16i CO Original installation and operation manual 28 76 ...

Страница 29: ...outside of areas exposed to direct sunlight and heat sources NOTE Handling packaging material Inappropriate disposal of packaging materials can cause environmental damage Dispose of the packaging material in accordance with the applicable legal requirements and provisions of the country and place of use 5 1 Transport After transporting and removing the packaging material inspect the product for po...

Страница 30: ...und the working area during assembly installation maintenance and repair work Before pressurisation check all system pipe connections for leak tightness and tighten if necessary Slowly pressurise the system Avoid pressure blows and high differential pressures Assemble all pipes free of mechanical stress Install the feed lines and drain lines as fixed pipes WARNING Insufficient qualification Insuff...

Страница 31: ... as the feed line ensure a continuous slope 3 Do not form water pockets 3 Continuous slope 3 in pipes When installing the feed line pipe ensure a continuous slope 3 Do not form water pockets If installation height is limited install the lower inlet with a separate venting line 3 Continuous slope 3 in pipes When installing the feed line pipe ensure a continuous slope 3 Do not form water pockets Ori...

Страница 32: ...ressure increases by 0 1 bar g 1 5 psi g per metre of incline Manifold design The cross section of the manifold must be at least equal to the sum of the individual cross sections of the connected feed lines Lay the manifold with a continuous slope 3 Diameters of the connected lines The minimum diameter of the feed line and the drain line must be at least 1 2 interior diameter at least 13 mm 0 5 in...

Страница 33: ...tes must be fulfilled and the preparatory tasks must have been completed Prerequisites Tools Material Protective equipment Spanner or adjustable end wrench Sealants e g PTFE Feed line Drain line Hose interior diameter 8 10 mm 0 31 0 39 in length approx 30 cm 1 ft Hose clamp Always to be worn Preparatory tasks 1 Depressurise the pressurised system or the respective system section and secure it agai...

Страница 34: ...X5 X4 X2 X3 F F G G X5 Recommendation For product maintenance install the shut off valves X3 X4 in the venting line X2 and in the condensate inlet line X5 5 For the condensate inlet line X5 and venting line X2 seal the end of a pressure resistant pipe and screw into the condensate inlet F and connection for the venting line G BEKOMAT 16i CO Original installation and operation manual 34 76 ...

Страница 35: ...D 6 For the condensate discharge fit the hose X6 provided to the drain connection D and use a hose clamp for fixation 7 Connect the other end of the hose X6 with the condensate discharge line X7 Original installation and operation manual BEKOMAT 16i CO 35 76 ...

Страница 36: ...and repair work Adhere to all applicable regulations e g VDE 0100 IEC 60364 ATEX during installation Connect the protective conductor earth connection according to regulations WARNING Insufficient qualification Insufficient qualification of the personnel carrying out work on the product and accessories can lead to accidents personal injury and damage to property as well as impair operation All wor...

Страница 37: ... angle 90 over high voltage cables Only use shielded connection cables for signal transmission Connect the shielding of the connection cables at least to the ground potential or shielding connection of the Modbus server device 7 2 Connection work For connection work to be carried out the following prerequisites must be fulfilled and the preparatory tasks must have been completed Prerequisites Tool...

Страница 38: ...tly and pull the terminal clamp 10 off 4 Remove the plug 7 and screw the cable gland components 4 5 6 off the right cable gland B 6 mm 50 mm 1 97 in 0 23 in 5 Prepare the connection cable X8 4 X8 B 5 6 6 Fit the cable gland components 4 5 6 over the connection cable X8 7 Insert the connection cable X8 into the right cable gland B BEKOMAT 16i CO Original installation and operation manual 38 76 ...

Страница 39: ...erminal diagram power control board on Page 28 B 4 X8 5 6 10 9 Screw the cable gland components 4 5 6 onto the right cable gland B 10 Fit the screw terminal 10 2 1 11 Set the top cover 2 in place and insert the screws 1 12 Tighten the screws 1 with a torque of 0 5 Nm 0 30 Nm 0 37 ft lb 0 22 ft lb Original installation and operation manual BEKOMAT 16i CO 39 76 ...

Страница 40: ...5 2 10 C 3 B 4 6 7 3 Raise the top cover 2 slightly and pull the terminal clamp 10 off 4 Remove the plugs 7 and screw the cable gland components 4 5 6 off the right cable gland B and left cable gland C 5 Remove the dust protection pane 3 6 mm 50 mm 1 97 in 0 23 in 6 Prepare connection cable X8 and connection cable X9 BEKOMAT 16i CO Original installation and operation manual 40 76 ...

Страница 41: ... cable X8 10 Connect connection cable X8 and connection cable X9 according to the terminal diagram 4 7 Terminal diagram power control board on Page 28 B 4 C 4 X8 5 6 X9 5 6 10 11 Draw cable X8 and connection cable X9 taut 12 Screw the cable gland components 4 5 6 onto the right cable gland B and the left cable gland C 13 Fit the screw terminal 10 2 1 14 Set the top cover 2 in place and insert the ...

Страница 42: ...pipe connections for leak tightness and tighten if necessary Slowly pressurise the system Avoid pressure blows and high differential pressures DANGER Electric voltage There is a danger of death or serious injuries as well as malfunction and device failure following contact with components which are in contact with electric voltage Only operate the product with the cover complete and closed or the ...

Страница 43: ...s out the power on self test 2 Slowly pressurise the system e g by slowly opening the recommended shut off valve X4 in the condensate inlet line X5 0 Slowly open the shut off valve X3 in the venting line 3 Carry out a functional test see 10 3 2 Functional test on Page 54 Original installation and operation manual BEKOMAT 16i CO 43 76 ...

Страница 44: ... amended or restricted by the use of accessories Adhere to the maintenance intervals DANGER Electric voltage There is a danger of death or serious injuries as well as malfunction and device failure following contact with components which are in contact with electric voltage Only operate the product with the cover or housing complete and closed NOTE Operating personnel Insufficient knowledge of the...

Страница 45: ...n The solenoid valve is cycling 0 The BEKOMAT switches to normal operation n 20 n Negative power on self test number of repetitions n 20x The red ALARM LED is on The green VALVE LED is on while the solenoid valve is cycling The green POWER LED is on The solenoid valve is cycling 0 The BEKOMAT goes into fail safe operation continuous loop n The solenoid valve is cycling once per second Ready for op...

Страница 46: ...he red ALARM LED is on The green VALVE LED is off The green POWER LED is on n Alarm mode condensate discharge is impaired The red ALARM LED flashes The green POWER LED is on The green VALVE LED is on when the solenoid valve is cycling 0 The solenoid valve is cycling every 4 minutes After the malfunction has been eliminated the BEKOMAT automatically switches to normal operation For further informat...

Страница 47: ...itched back on again unintentionally Set up a safety area around the working area during all maintenance and repair work Only operate the product with the cover complete and closed or the housing closed DANGER Use of incorrect spare parts accessories or materials The use of incorrect spare parts accessories or materials as well as auxiliary and operating materials may result in death or serious in...

Страница 48: ...art replacement since all parts are disassembled at this point 10 3 Maintenance work For maintenance work to be carried out the following prerequisites must be fulfilled and the preparatory tasks must have been completed Prerequisites Tools Material Protective equipment Screwdriver flat head size 2 5 mm 0 09 Spanner or adjustable end wrench Sealants Suitable lubricant for greasing the O rings Mild...

Страница 49: ...ustration Description explanation 49 50 1 Loosen the screw 49 of the solenoid valve connector 50 50 2 Pull the solenoid valve connector 50 off 26 E 3 Loosen the screws 26 from the valve unit E Original installation and operation manual BEKOMAT 16i CO 49 76 ...

Страница 50: ...r part replacement Illustration Description explanation E 4 Take the valve unit E off 32 5 Loosen the screws 32 and take the valve unit apart BEKOMAT 16i CO Original installation and operation manual 50 76 ...

Страница 51: ...t replacement Illustration Description explanation 40 33 34 6 Loosen the nuts 34 with the spring washers 33 and take the housing upper part 40 off Original installation and operation manual BEKOMAT 16i CO 51 76 ...

Страница 52: ... set of wear parts X 8 Grease the O rings in the set of wear parts 40 33 34 9 Set the housing upper part 40 in place again and screw tight using the nuts 34 and spring washers 33 10 Tighten the nuts 34 with a torque of 20 Nm 5 Nm 14 75 ft lb 3 69 ft lb BEKOMAT 16i CO Original installation and operation manual 52 76 ...

Страница 53: ...Re assemble the solenoid valve as shown and tighten using the screws 32 12 Tighten the screws 32 with a torque of 1 5 Nm 0 5 Nm 1 11 ft lb 0 37 ft lb E 13 Place the valve unit E back on the membrane cap Original installation and operation manual BEKOMAT 16i CO 53 76 ...

Страница 54: ...lve connector 50 and screw tight using the screw 49 17 Tighten the screw 49 with a torque of 1 0 Nm 0 2 Nm 0 74 ft lb 0 15 ft lb 10 3 2 Functional test Illustration Description explanation Press the TEST button for 2 5 seconds 0 The red ALARM LED is off 0 The green VALVE LED is on 0 The green POWER LED is on 0 The valve opens and condensate is drained BEKOMAT 16i CO Original installation and opera...

Страница 55: ...ightness in vacuum and overpressure systems The leakage test can be carried out in different ways BEKO TECHNOLOGIES provides no recommendations for selecting a testing process The operating company of the pressurised system is responsible for the selection and specification of the test method to be used which should be executed in corresponding to with valid standards and regulations e g DIN EN 17...

Страница 56: ...arkings that have become illegible NOTE Local hygiene regulations In addition to the cleaning instructions listed any regionally applicable hygiene regulations must be observed Prerequisites Tools Material Protective equipment Cleaning brush Mild cleaning agent Cotton or disposable cloth Always to be worn Preparatory tasks 1 Decommissioning and disassembly of the BEKOMAT have been completed 2 The ...

Страница 57: ...cleaning brush Ø max 2 5 mm 0 09 4 Clean the guide bushings for the control air pipe and the control air pipe itself using a cleaning brush Ø max 2 5 mm 0 09 5 Clean the membrane cap using a cleaning brush Ø max 1 5 mm 0 05 Original installation and operation manual BEKOMAT 16i CO 57 76 ...

Страница 58: ...ean the membrane cap using a cleaning brush Ø max 2 5 mm 0 09 Concluding work 1 Put the BEKOMAT together 2 Assemble the BEKOMAT see 6 Assembly on Page 30 3 Put the BEKOMAT into operation see 8 Commissioning on Page 42 4 Reset the service intervals see 3 4 3 4 Control commands on Page 22 BEKOMAT 16i CO Original installation and operation manual 58 76 ...

Страница 59: ...r spare parts to be delivered The contact data for the BEKO TECHNOLOGIES customer services responsible are listed in chapter 1 1 Contact on Page 5 11 2 Accessories Illustration Description Material no Mounting bracket for wall and floor 2000038 Trace heater 230 VAC 4041657 Thermostatically controlled heating system 200 230 VAC 2801244 100 115 VAC 2801245 24 VAC VDC 2801247 Connection set 2000044 D...

Страница 60: ... The software can be downloaded from the BEKO TECHNOLOGIES homepage see 1 1 Contact on Page 5 11 3 Spare parts Illustration Description Material no X X X X X X X X X X Set of wear parts contains the marked components X 2000087 BEKOMAT 16i CO Original installation and operation manual 60 76 ...

Страница 61: ...Illustration Description Material no Membranes 3 pieces 4002451 Valve unit 2000089 Original installation and operation manual BEKOMAT 16i CO 61 76 ...

Страница 62: ...Illustration Description Material no X X X X X X X X Valve attachment components contains the marked components X 2000088 BEKOMAT 16i CO Original installation and operation manual 62 76 ...

Страница 63: ...Illustration Description Material no Set of seals 2000090 Housing main part 2000092 Original installation and operation manual BEKOMAT 16i CO 63 76 ...

Страница 64: ...Illustration Description Material no Housing lid 2000066 Top cover 2000066 BEKOMAT 16i CO Original installation and operation manual 64 76 ...

Страница 65: ...and device failure following contact with components which are in contact with electric voltage Only carry out maintenance and repair work on the product when it has been disconnected and secured against being switched back on again unintentionally Set up a safety area around the working area during all maintenance and repair work WARNING Insufficient qualification Insufficient qualification of th...

Страница 66: ...ommended shut off valve X4 2 Close the venting line X2 e g using the recommended shut off valve X3 3 Press the TEST button briefly multiple times 0 The pressure in the BEKOMAT is reduced 0 The condensate remaining in the BEKOMAT is drained 4 Disconnect the BEKOMAT from the voltage supply and switch off all power BEKOMAT 16i CO Original installation and operation manual 66 76 ...

Страница 67: ...d device failure following contact with components which are in contact with electric voltage Only carry out maintenance and repair work on the product when it has been disconnected and secured against being switched back on again unintentionally Set up a safety area around the working area during all maintenance and repair work WARNING Insufficient qualification Insufficient qualification of the ...

Страница 68: ...erequisites Tools Material Protective equipment Spanner or adjustable end wrench No material necessary Always to be worn Preparatory tasks 1 Decommissioning has been completed 2 Depressurise the pressurised system or the respective system section and secure it against unintentional pressurisation BEKOMAT 16i CO Original installation and operation manual 68 76 ...

Страница 69: ... recommended shut off valve X4 from the condensate inlet F and disassemble 7 Loosen the venting line X2 and the recommended shut off valve X3 from the connection for the venting line G and disassemble 8 Disassemble all power supplies 13 2 1 Concluding work Concluding work 1 Clean the components of condensate residue see 10 3 5 Cleaning on Page 56 Original installation and operation manual BEKOMAT ...

Страница 70: ...cal and electronic equipment WEEE is not disposed of properly Electrical and electronic equipment are marked by the crossed out rubbish bin The crossed out rubbish bin symbolises that electrical and electronic equipment must be collected separately and must not be disposed of together with unsorted domestic waste For this purpose all communities have set up collecting systems where waste from elec...

Страница 71: ... materials filter materials cleaning wipes and protective clothing contaminated by oils or other hazardous substances 15 02 02 Adsorption materials filter materials cleaning wipes and protective clothing with the exception of those classified by 15 02 02 15 02 03 Packaging paper and cardboard 15 01 01 Packaging plastic material 15 01 02 Electric and electronic devices with the exception of those c...

Страница 72: ...ter 5 seconds Inspect the circuit board for potential damage No condensate is drained after the TEST button has been pressed Check the feed line and the drain line Replace wear parts Check the valve function by pressing the TEST button 0 Valve switching can be heard clearly clicking sound Check the connection terminals on the control circuit board The condensate is only drained when the TEST butto...

Страница 73: ...of TÜV Rhineland for the Canadian and US American market and that basic safety and health requirements were met during manufacturing of the product The product may be sold on the Canadian and US American market EAC marking The EAC marking indicates that a product fulfils all the Eurasian directives applicable for this product and that basic safety and health requirements were met during manufactur...

Страница 74: ...16 2 Declaration of Conformity BEKOMAT 16i CO Original installation and operation manual 74 76 ...

Страница 75: ...Original installation and operation manual BEKOMAT 16i CO 75 76 ...

Страница 76: ...4 610 780 639 info es beko technologies es BEKO TECHNOLOGIES LIMITED Room 2608B Skyline Tower No 39 Wang Kwong Road Kwoloon Bay Kwoloon Hong Kong Tel 852 2321 0192 Raymond Low beko technologies com BEKO TECHNOLOGIES INDIA Pvt Ltd Plot No 43 1 CIEEP Gandhi Nagar Balanagar Hyderabad IN 500 037 Tel 91 40 23080275 91 40 23081107 Madhusudan Masur bekoindia com service bekoindia com BEKO TECHNOLOGIES S ...