15. Troubleshooting / FAQ
Illustration
Description / explanation
Troubleshooting
All LEDs off
•
Read the operating voltage off on the type plate
and check it
• Check whether voltage is applied to the terminals
of the power control board (PE, L, N)
• Check the plug-type connection of the cable
terminal on the control PCB
TEST button has been
pressed but no condensate is
being drained
• Check feed and discharge lines
• Replace wear parts
• Check whether the valve clocking can be heard, to
do this press the TEST button several times
• Check the plug-type connection of the cable
terminal on the control PCB
Condensate is only drained
when the TEST button is
pressed
• Install feed line at a gradient >3%
• Mount venting line
• Clean sensor tube
• Check whether the necessary minimum pressure
has been reached, if not:
0
install
BEKOMAT
®
vacuum discharge
Device constantly blows off
air
• Clean entire valve unit
• Replace wear parts
• Clean sensor tube
Original installation and operation manual
BEKOMAT
®
16 CO
53 | 60
Содержание BEKOMAT 16 CO
Страница 1: ...EN BEKOMAT 16 CO 01 3582 Original installation and operation manual BM16CO ...
Страница 55: ...Original installation and operation manual BEKOMAT 16 CO 55 60 ...
Страница 58: ...BEKOMAT 16 CO Original installation and operation manual 58 60 ...
Страница 59: ...Original installation and operation manual BEKOMAT 16 CO 59 60 ...