3.3 Function description
Illustration
Description / explanation
C
21
46
The condensate flows via the condensate inlet
[C]
into the
BEKOMAT
®
and collects in the housing
[21]
. The filling
level in the housing
[21]
is permanently monitored by a
capacitive sensor in the sensor tube
[46]
.
30
25
B
The control actuates the pilot valve with valve core
[30]
and the membrane
[25]
opens the condensate
discharge
[B]
to the condensate drain system.
Once the
BEKOMAT
®
has been emptied, the condensate
discharge
[B]
is closed tightly again before any loss of
compressed gas can occur.
BEKOMAT
®
16 CO
Original installation and operation manual
12 | 60
Содержание BEKOMAT 16 CO
Страница 1: ...EN BEKOMAT 16 CO 01 3582 Original installation and operation manual BM16CO ...
Страница 55: ...Original installation and operation manual BEKOMAT 16 CO 55 60 ...
Страница 58: ...BEKOMAT 16 CO Original installation and operation manual 58 60 ...
Страница 59: ...Original installation and operation manual BEKOMAT 16 CO 59 60 ...