background image

Operation

  

Operating manual AVERO Phoenix  

V2.1 E 

Page 17 of 35 

 

 

8. 

Operation 

8.1  Prior to use 

Please check the proper state and the functional safety of the system prior to use. 

8.2  During use 

The AVERO Phoenix lifting bath tub is free standing on three sides and requires only 
little space 

 

If you want to fill the AVERO Phoenix lifting bath tub, press button 8 or 9 on the control 
panel to start the filling of the bath tub. 

If your bath tub is equipped with the optional function “automatic water stop”, the filling 

is automatically switched off when the filling height is reached. 

If this option is not available on your bath tub, you must interrupt the filling process by 
pressing the button 8 or 9 

 again  

 

Note! 

 

Before the patient steps into the bath tub, the water temperature 

must be checked manually (without wearing gloves) either with 

a thermometer. 

 

To facilitate the access to the bath tub for the patient, press the   button to sink the 
bath tub to the lowest position. 
Now, you can install the patient in the bath tub. 

 

Wheelchair users can be easily lifted into the AVERO Phoenix lifting bath tub by 
means of mobile lift systems, ceiling lifts etc. The large opening underneath the bath 
tub provides for direct access with almost any lifting system. 

 

The integrated seat in the bath tub improves the sitting position of the patient. In the 
bath tub, two handles are provided to enhance the safety. The tub body of the AVERO 
Phoenix lifting bath is equipped with 3 longitudinal guides, in which the tub size 
reducer can be inserted. 

 

To put the patient in the desired position, you must press the button 

” or “

” to 

lower either to raise the bath tub. 
If the desired position is reached, you can release the button. 

 

If the bathing process is finished, turn the eccentric knob (overflow) to drain the water. 
You can already start towelling the patient, when he or she is still sitting comfortably in 
the bath tub. 

 

Help the patient to get out of the bath tub. 
To this effect, you can also use a lift system. 

Please make sure that the bath tub is always disinfected and rinsed prior to use it for 
the next patient. 

 

If your bath tub features an integrated disinfecting system, you can disinfect your tub 
with the (yellow) disinfecting hand shower. 

 

Содержание AVERO Phoenix

Страница 1: ...AVERO Phoenix Lifting bath tub Version 2 1 English Subject to technical modifications 2020 11 17 Operating manual Original operating manual...

Страница 2: ...List of used safety instructions 8 4 5 Warnings 9 5 Transport 10 5 1 Unpacking the product 10 5 1 1 Removing the cardboard 10 5 1 2 Loosening the product from the pallet 10 6 Installation 11 6 1 Elec...

Страница 3: ...sposal 20 11 1 Disposal of the packaging material 20 11 2 Disposal of the product 20 12 Troubleshooting After sales service 21 12 1 Troubleshooting help 21 13 Appendix 23 13 1 Technical data 23 13 2 D...

Страница 4: ...ured and tested according to stringent quality criteria 1 2 Manufacturer s address BEKA Hospitec GmbH Am R benmorgen 3 35582 Wetzlar Phone 49 0 641 9 22 22 0 Fax 49 0 641 9 22 22 20 info beka hospitec...

Страница 5: ...ll as the national regulations laws and prescriptions related to work safety and accident prevention The manufacturer of the product is only responsible for the safety and the reliability of the produ...

Страница 6: ...bly of individual components of the product Please read the operating manual and the safety instructions before starting to use the product Keep the operating manual near the device for future referen...

Страница 7: ...iptions 0100 and 0100 710 However have a specialist company check the compliance of your electrical installation with the applicable prescriptions prior to operating and using the product This require...

Страница 8: ...B to DIN EN 60601 1 Special waste no household waste The device and the packaging materials never must be disposed of in the domestic waste stream CE label in accordance with the EC Directive on Medic...

Страница 9: ...vice in the immediate vicinity of the device is strictly forbidden Mobile telephony could also cause interference Route the mains and the connecting cable so that they cannot be damaged Damaged mains...

Страница 10: ...ter in the cardboard 5 1 1 Removing the cardboard Proceed in the following way to remove the cardboard Cut the strap with the cutter knife Remove the strap Lift the cardboard up to remove it and put i...

Страница 11: ...of the bath tub must be executed in accordance with the technical drawings issued by BEKA Hospitec either the guidelines for the set up and layout of wet areas and the current VDE standards All suppl...

Страница 12: ...accordance with the local water supply prior to the first use Please consult the attached user manual to this effect The settings must be documented NOTE In order to ensure a safe functioning and oper...

Страница 13: ...Sound system optional 7 Eccentric plug and tub inlet 3 Hand shower 8 Thermostatic mixer with scalding protection 4 Tub handle 9 Aroma system optional 5 Head neck support optional N Description N Descr...

Страница 14: ...height of the bath tub can be individually adjusted If you press the UP button the bath travels up If you press the DOWN button the bath travels down 7 1 2 The hand shower The hand shower is switched...

Страница 15: ...y Once the second filling height is reached the bath tub can no longer be automatically filled In this case you can add additional water to the tub by manually pressing button 9 Note Supervision of th...

Страница 16: ...the DIS button to switch the disinfection on If the disinfection LED is permanently yellow the disinfection is activated Press again on the DIS button to switch off the disinfection system The disinfe...

Страница 17: ...bath tub Wheelchair users can be easily lifted into the AVERO Phoenix lifting bath tub by means of mobile lift systems ceiling lifts etc The large opening underneath the bath tub provides for direct a...

Страница 18: ...lvents must be used to clean the keypad Please remember that all warranty claims regarding surface damage will not be accepted if aggressive cleaning agents are anyhow used 9 2 Disinfecting the liftin...

Страница 19: ...loyer s liability insurance association on stationary equipment which is used in special locations or installations an annual check to the DGUV German Statutory Accident Insurance Association Prescrip...

Страница 20: ...nents must be recycled in accordance with the WEEE 11 2 Disposal of the product The expected service life of the lifting bath tub is approx 8 years At the end of the product s lifetime contact your BE...

Страница 21: ...o not lit Check if the fuse and the fault current circuit breaker are activated Mains voltage fails a Check fuse b Check the cables for damages No water a Check the shut off valves of the cold and hot...

Страница 22: ...pa system fails during operation a The air spa system has been used for over 15 minutes Let the air spa system cool down b Overheating due to too high an ambient temperature Let the air spa system coo...

Страница 23: ...kg Fill volume 190 without patient approx 220 l Fill volume 170 without patient approx 190 l Patient s weight max 220 kg SWL safe workload 300 kg patient and water Applied part Type B Protection class...

Страница 24: ...Appendix Operating manual AVERO Phoenix V2 1 E Page 24 of 35 13 2 Dimensions of the AVERO Phoenix 190...

Страница 25: ...Appendix Operating manual AVERO Phoenix V2 1 E Page 25 of 35 13 3 Dimensions of the AVERO Phoenix 170...

Страница 26: ...e Installed connection Sanitary Electric Warm water connection set female threading tile even Assemble hexagon nipple elbow 90 ball valve strainer and rosette see details illustration Pos 1 und 2 Cold...

Страница 27: ...Appendix Operating manual AVERO Phoenix V2 1 E Page 27 of 35 13 5 Declaration of Conformity...

Страница 28: ...150 Aroma system 910150587 Emergency function at power failure K9103300 Nina hand shower K9100363 Shower hose L 2 3m K9100951 Disinfectant shower yellow K9100351 Shower hose for disinfection yellow L...

Страница 29: ...r listed ELECTROMAGNETIC ENVIRONMENTS The customer or the user of the AVERO Phoenix must ensure that the appliance is used in such environment Emission measurements Compliance Electromagnetic environm...

Страница 30: ...quality of the supply voltage should match that of a typical business or hospital environment Overvoltage IEC 61000 4 5 1 kV cable against cable 2 kV cable against ground connection 1 kV cable against...

Страница 31: ...h of fixed HF transmitters as determined by an electromagnetic field survey a should be less than the COMPLIANCE LEVEL in each frequency range b In the vicinity of equipment marked with the following...

Страница 32: ...distance depending on the transmitting frequency in m 150 kHz to 800 MHz d 0 35 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 1 1 10 100 0 04 0 11 0 35 1 1 3 5 0 12 0 38 1 2 3 8 12 0...

Страница 33: ...morgen 3 35582 Wetzlar Serial number _____________________________________________ Date of purchase _____________________________________________ Site _____________________________________________ Che...

Страница 34: ...Appendix Operating manual AVERO Phoenix V2 1 E Page 34 of 35 Periodic inspection repair DGUV 3 safety check etc Type of inspection Date Result Measure Signature...

Страница 35: ...BEKA Hospitec GmbH Am R benmorgen 3 35582 Wetzlar Germany Phone Fax 49 0 6 41 9 22 20 0...

Отзывы: