Beer Grill AG
Beer Grill GmbH
Allmendstrasse 7
Tel. +41 (0)56 618 7800
Körnerstrasse 14 a
Tel. +49 (0)71 61 659 876
CH
– 5612 Villmergen
Fax +41 (0)56 618 7849
D
– 79539 Lörrach
Fax +49 (0)71 61 659 879
www.beergrill.com
Page 11
Fuses:
Type
GN 2/1
GN 3/1
GN 4/1
GN 5/1
Power (kW)
2.10
3.15
4.20
5.25
Connection CH
Fuse (A)
AC230 V
10 A
2AC400 V
10 A
2AC400 V
10 A
3AC400 V
10 A
Connection EU
Fuse (A)
AC230 V
10 A
AC230 V
16 A
2AC400 V
10 A
3AC400 V
10 A
5.2 Sanitary connection
To avoid odour emissions the Culinario should be connected to a fix drain with siphon. The
drain (option) has a 1½
"
outside thread. The inside-diameter of the drain tube should be not
less then 1½
"
.
6
Dry Run Warning
The Culinario Master Touch is equipped with a dry run warning. After 3 hours operation with
water bowls, this emits an acoustic and visual signal and reduces the bottom burner to
protect the materials.
If a message from the dry run protection system is not confirmed, the
bottom burner reduced and your food is no longer kept warm!
The water level must be checked every 3 h and if necessary refilled with
hot water.
Important note:
Layers of calcium deposits reduce the transfer of heat to the water in the
dishes and result in damages and increase energy consumption.
!
!
!