Commissioning/configuration of IO-Link master/device
EPI3xxx, ERI3xxx
34
Version: 1.2
Online scanning in Config mode
The online search is not available in RUN mode (production operation).
Note the differentiation between TwinCAT programming system and TwinCAT target system. The
TwinCAT icon next to the Windows clock always shows the TwinCAT mode of the local IPC. The
System Manager window shows the TwinCAT state of the target system.
Right-clicking on “I/O Devices” in the configuration tree opens the search dialog.
Fig. 31: Scan Devices
This scan mode not only tries to find EtherCAT devices (or Ethernet ports that can be used as such), but
also NOVRAM, fieldbus cards, SMB etc. Not all devices can be found automatically.
Fig. 32: note for automatic device scan
Ethernet ports with installed TwinCAT real-time driver are shown as “RT Ethernet” devices. An EtherCAT
frame is sent to these ports for testing purposes. If the scan agent detects from the response that an
EtherCAT slave is connected, the port is shown immediately as an “EtherCAT Device”.