8.2
Guide to electrical installation
The following notes should assist you to carry out the electrical installation in a sensible sequence,
without overlooking anything important.
Cable selec-
tion
Select cables according to EN 60204 (
ð
p. 20)
Grounding
Shielding
EMC-compliant (EMI) shielding and grounding (
ð
p. 45)
Earth (ground) the mounting plate, motor housing and CNC-GND of the controls.
Notes on connection techniques are on page 40
Wiring
Route power leads and control cables separately
Wire the BTB/RTO contact in series into the safety loop
— Connect the digital control inputs to the servo amplifier
— Connect up AGND (also if fieldbuses are used)
— Connect the analog setpoint, if required
— Connect up the feedback unit (resolver and/or encoder)
— Connect the encoder emulation, if required
— Connect the expansion card (see corresponding manual on the CD-ROM)
— Connect the motor cables, connect shielding to EMI connectors at both ends
— Connect motor-holding brake, connect shielding to EMI connectors at
both ends
— Connect the external regen resistor (with fusing)
— Connect aux. supply (for max. permissible voltage values
ð
p. 19)
— Connect mains choke and mains filter (shielded lines between filter and
servo amplifier)
— Connect main power supply (for max. permissible voltage values
ð
p. 19)
— Connect PC (
ð
p. 67).
Final check
— Final check of the implementation of the wiring,
—
according to the wiring diagrams which have been used.
38
AX2040/2070 Product Manual
Electrical Installation
06/2007
BECKHOFF
Содержание AX2040
Страница 35: ...7 4 Dimensions AX2040 2070 Product Manual 35 BECKHOFF 06 2007 Mechanical Installation...
Страница 44: ...8 6 Pin assignments 44 AX2040 2070 Product Manual Electrical Installation 06 2007 BECKHOFF...
Страница 108: ...This page has been deliberately left blank 108 AX2040 2070 Product Manual Expansion Cards 06 2007 BECKHOFF...