8.14.2
Analog outputs (X3)
Technical characteristics
—
Reference ground is analog-GND (AGND, terminal X3/1 and X3/10)
—
Output resistance : 2.2 k
W
—
Output voltage
±
10 V
—
Resolution : 10 bit.
—
Update rate 62.5 µs
Programmable analog outputs Analog-Out 1 / Analog-Out 2
The terminals X3/8 (Analog-Out 1) or X3/9 (Analog-Out 2) can have the following analog signals
assigned to them:
Standard setting :
Analog-Out 1
: Tachometer voltage
n
act
(speed)
The output delivers
±
10 V at the preset limit speed.
Analog-Out 2
: Current actual value
I
act
(torque)
The output delivers
±
10 V at the preset peak current (effective r.m.s. value).
You can use the terminals X3/8 (Analog-Out 1) or X3/9 (Analog-Out 2) to output converted analog
values for digital measurements which are contained in the servo amplifier.
You can find a list of pre-programmed functions on the "analog I/O" screen of our setup software.
64
AX2040/2070 Product Manual
Electrical Installation
06/2007
BECKHOFF
AX2040/2070
Содержание AX2040