9.4
Multi-axis system
Using a special multilink cable, you can connect up to six servo amplifiers together and to your PC :
Cable type -SR6Y- (for 4 amplifiers) or -SR6Y6- (for 6 amplifiers).
With the PC connected to just one servo amplifier you can now use the setup software to select all
amplifiers through the preset station addresses and set up the parameters.
9.4.1
Node address for CAN-bus
During setup it makes sense to preset the station addresses for the individual amplifiers and the
baud rate for communication by means of the keypad on the front panel (
ð
p. 91).
9.4.2
Baud rate for CAN-bus
After changing the station address and baud rate you must turn the 24V auxiliary
supply of the servo amplifier off and on again.
Coding of the baud rate in the LED display :
Coding
Baud rate in kbit/s
Coding
Baud rate in kbit/s
0
10
5
250
1
20
6
333
2
50
7
500
3
100
8
666
4
125
9
800
10
1000
88