CAUTION:
This equipment is designed to permit the connection of the earthed conductor of the DC supply circuit to
the earthing conductor at the equipment.
If this connection is made, all of the following must be met:
• This equipment must be connected directly to the DC supply system earthing electrode conductor or
to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing
electrode conductor is connected.
• This equipment must be located in the same immediate area (such as adjacent cabinets) as any
other equipment that has a connection between the earthed conductor of the same DC supply circuit
and the earthing conductor, and also the point of earthing of the DC system. The DC system must be
earthed elsewhere.
• The DC supply source is to be located within the same premises as the equipment.
• Switching or disconnecting devices must not be in the earthed circuit conductor between the DC
source and the point of connection of the earthing electrode conductor.
HPE 1600W Flex Slot Platinum Hot Plug Power Supply
Specification
Value
Input requirements
Rated input voltage
200 to 240 VAC
240 VDC (China only)
Rated input frequency
50 Hz to 60 Hz
Rated input current
8.7 A at 200 VAC
7.2 A at 240 VAC
Maximum rated input power
1734 W at 200 VAC
1720 W at 240 VAC
BTUs per hour
5918 at 200 VAC
5884 at 240 VAC
Power supply output
Rated steady-state power
1600 W at 200 VAC to 240 VAC input
1600 W at 240 VDC input
Maximum peak power
2200 W for 1ms (turbo mode) at 200 VAC to 240 VAC
input
HPE 1600W Flex Slot Platinum Hot Plug Power Supply
153
Содержание BCD221
Страница 7: ...Documentation feedback 157 Contents 7 ...
Страница 27: ...Component identification 27 ...
Страница 43: ...Operations 43 ...
Страница 74: ...9 Install the optical disk drive tray 10 Install the universal media bay 74 Hardware options installation ...
Страница 80: ...Remove the secondary wall blank 6 Remove the tertiary wall blank 80 Hardware options installation ...
Страница 81: ...7 Install the drive cage compatible rear wall 8 Install the drive cage Hardware options installation 81 ...
Страница 123: ...LFF models Cable routing Front 8SFF drive options Box 1 to SAS Expander Cable routing Front 8SFF drive options 123 ...
Страница 124: ...Box 2 to SAS Expander All boxes 124 Cabling ...
Страница 126: ...Box 2 Box 3 126 Cabling ...
Страница 127: ...Cable routing Front 2SFF NVMe drive option for SFF Cable routing Front 2SFF NVMe drive option for SFF 127 ...