Installation manual
HB-37420-810-01-25F-EN SMX100 Installation manual.docx
Page 63 of 260
Version: 25F
Technical characteristic data: SMX5x
Safety related characteristic data
Pl acc. to EN ISO 13849-1
n.a.
PFH / architecture
n.a.
SIL acc. to IEC 61508
n.a.
Proof test interval
n.a.
General data
Fieldbus interface
1
Type of connection
Standard acc. to field bus type
Max. size PAA
2x64 Bit
Max. size PAE
32 Bit
Type Update time for data
16 ms
Electrical data
Power consumption
Max. 0,5W
Field bus ratings
Standard acc. to field bus type
Environmental data
Temperature
0°C … +50°C operation
-
25C° … +70C°storage and transport
Class of protection
IP 20
Climatic category
3k3 acc. to DIN 60 721-3
Min-, Maximum relative humidity
(no condensation)
5% - 85%
EMC
EN 61000-6-2, EN 61000-6-4, EN 61000-6-7, EN
61800-3, EN 61326-3, EN 62061
Operating materials
2000m
Overvoltage category
III
Degree of contamination
2
Mechanical data
Dimensions
(HxDxW [mm])
100x115x22,5
Weight
(g)
110
Fastening
To snap on top-hat rail