33
Safety information for performing installation, start-up, and maintenance work
User Manual PoolManager
®
69
Part C:
Installation, start-up, maintenance
Requisite user qualification:
TRAINED SPECIALIST
All activities described in Part C may only be performed
by TRAINED SPECIALISTS as defined in the Chapter
User Qualification.
33
Safety information for performing installation,
start-up, and maintenance work
HAZARD!
Hazard from electrical current
PoolManager
®
begins to run as soon as there is
voltage on the incoming power line. It is possible that
dosage pumps start or that add-on functions are
turned on or toggled. Contact with current-carrying
components can lead to an electrical shock.
Potential consequence: Grave health hazard and
death, material damage
•
Installation and maintenance work on the unit
must always be performed in a potential free
state.
•
The unit must be secured against turning on
while performing work!
•
Add-on component groups have to be
mounted/dismounted in a potential free state.
•
Cables also have to be connected in a
potential-free state.
•
There should always be safety equipment
present that is independent of the controller.
•
Password protection must be activated as
needed.
•
The country's local safety requirements must
be met.
•
Immediately after completing work, all safety
and security equipment must be reinstalled and
rendered functional.
•
Non-compliance with safety information can
lead to the unit becoming defective, to mortal
danger, and to warranty forfeit.
34
Wall mounting
HAZARD!
The unit is not suitable for installation in areas
exposed to explosion hazards.
34.1
Selecting the installation location
•
Level, flat surface.
•
The free space surrounding the unit must be large enough for
trouble-free operation and maintenance. Covers must remain
removable. Be sure that the electrodes are freely accessible in
order to guarantee trouble-free handling.
•
The control unit's casing opens to the left.
•
The control unit's display should be approximately at eye level.
•
At least 20-cm of clearance is needed underneath the unit for
installing hoses.
•
No parts sensitive to moisture underneath the unit
•
A damp room DC SCHUKO socket no more than 1.5 m away.
•
All hoses and cables must be installed free from kinks and
abrasion.
•
No hose line should be longer than 5 m.
•
Hoses may not be run directly over pipes or systems that
transmit heat.
•
Direct sunlight, thermal radiation, frost, and moisture must be
avoided.
•
Ensure sufficient ventilation.
•
No current-carrying lines, relays, electric motors, etc. in the near
vicinity.
•
The installation location should be as close to measurement
water extraction and return as possible.
34.2
Installation
•
The base plate can be used as a drill template by holding it on the
intended location and marking the drill holes on the wall.
•
After the base plate is safely anchored to the wall, including
mounted controller and measuring sensory, the covers can be
inserted into the tongue and groove connection supplied.
35
Electrical connection
PoolManager
®
is designed and built according to the applicable
guidelines. Prior to leaving the factory, it was carefully inspected and
departed from the factory in a state free of technical issues.
Hazard-free operation is only possible when all information included in
this manual is observed.
The supply current for the unit may not exceed 240V/50 Hz. The
permissible operating temperature is 0 to 50°C, permissible air
humidity is 0-90%.
As is standard with all electrical connections, be sure that all plug
connections are secured against water.
35.1
Measurement grounding
There must be a ground for both measurement water extraction and
return. The ground connections have to be connected with a safe
ground in order to facilitate the conduction of potential in pool water.
IMPORTANT NOTICE
The ground MUST be installed. Ensure that this
ground functions without issues.
Please always make sure that there is no residual
current to the swimming pool's water. In cases of
doubt, we recommend having measurement taken
professionally.
35.2
Blocking the circulation pump
PoolManager
®
is equipped with a double pump lock, which offers the
highest level of security. That is why it has 2 separate power
connections, with one power connection directly to the controller and
the other connection supplying the dosage pump.
On the one hand, the flow switch in the measuring cell ensures that
the dosage pump is only turned on when there is sufficient water in the
measuring cell.
On the other hand, the dosage pumps are supplied with a separate
current from the power supply. That power feed absolutely must be
connected such that the dosage pumps are only supplied with power
when the circulation pump is running.
This guarantees that the dosage pump only runs when the pool water
is being run through the circulation system.