21
User management
User Manual PoolManager
®
51
21.3
Overview of user rights
User level ►
▼ Function
Guest
(Level 0)
Customer
(Level 1)
Customer
(Level 2)
Service
(Level 3)
Master
(Level 4)
Factory
(Level 5)
Standard access code
-
1234
9876
8642
xxxx
xxxx
Complete menu navigation
"See everything - change nothing"
Setting uncritical parameters
Setting parameters critical to function
Setting parameters relevant to safety
Call-up mode menu
1-point calibration
2-point calibration
Manual dosing
Acknowledge acoustic alarm
Acknowledge alarms
Acknowledge service messages
Master (level 4) - Special functions
Factory (level 5) - Special functions
Function area permitted for the corresponding user level
Function area not permitted for the corresponding user level, but can be released by system operator.
21.4
Configure access rights for remote access
In the menu
Configure access rights for remote access
, multiple
settings regarding access rights in remote access can be made.
It can be defined whether remote access is allowed or not for various
functions. It is possible to configure the following settings:
Release of remote access
Inactive
Remote access to the corresponding function is
blocked.
Local network
Remote access to the corresponding function is
released on the local network only, but not on
the Internet (Web).
Local network & Web
Remote access to the corresponding function is
released both the local network and on the
Internet (Web).
Remote access can be released or blocked for the following functions:
Sub-menu
Configure access rights for remote access
Allow remote access mode
menu
Release of mode menu for remote access
Under certain circumstances, critical functions
can be turned on and off accidentally during
remote access to the Mode menu. That is why
the default setting blocks remote access to the
Mode menu.
Allow remote access
calibration
In general, calibration has to be performed on-
site. That is why the default configuration blocks
remote access to calibration.
If needed, however, calibration can be released
for remote access if, for example, a mobile
device is going to be used on-site.
Allow
remote access
manual dosing
In general, manual dosing has to be performed
on-site. That is why the default setting blocks
remote access to the manual dosing. If needed,
however, calibration can be released for remote
access if, for example, a mobile device is going
to be used on-site.
21.5
Adjust requisite
user level for functions
In the menu
Adjust requisite user level for functions
, the requisite user
level for access to various functions can be adjusted as needed:
Sub-menu
Adjust requisite user level for functions
User level
for Mode menu
Requisite user level for access to the Mode
menu.
Potential settings:
•
Customer (level 0) (
no login!)
•
Customer (level 1)
User level
for 1-point calibration
Requisite user level for
1-point calibration.
Potential settings:
•
Customer (level 1)
•
Customer (level 2)
User level
for manual dosing
Requisite user level for
manual dosing.
Potential settings:
•
Customer (level 1)
•
Customer (level 2)
21.6
User login with access code
Most parameter changes and access to some menus require
authentication with a certain user level. If authentication is required,
then the menu
User login
will appear automatically.
In this menu, first chose the user with the access code you would like
to use for login. Then enter the correct access code for the selected
user. If the access code entered is correct, then you'll be granted
access to the secure area.
•
After successful login, the corresponding user level will remain
valid until you return to home view; or, after several minutes the
screen is returned to home view automatically.
•
No new login is necessary for as long as the user level is still