8.2.9.
Checking the condensate trap
CAUTION
First remove the front housing of the boiler so that you can
disconnect the condensate trap.
1. Move the lever underneath the hydroblock to the right to
disconnect the condensate trap.
2. Remove the condensate trap and clean it.
3. Replace the seal ring for the condensate trap.
4. Fill the condensate trap with water up to the mark.
5. Press the condensate trap firmly into the
j
opening provided for
it underneath the boiler. The condensate trap must click into place.
6. Check whether the condensate trap is solidly fitted in the boiler.
R000431-B
6
5
2
4
3
1
8. Checking and maintenance
Baxi MainEco Combi and System 24 - 28 - 35 / 18 - 24
56
02092014 - 7619497-02