4.3
Skeleton Diagrams
Combi 24 - 28 - 35
1
Primary heat exchanger
2
Hydroblock
3
Plate heat exchanger (DHW)
4
Safety valve
5
Heating flow
6
Domestic hot water outlet (DHW)
7
Domestic cold water inlet
8
Heating return
9
Circulation pump (Central heating)
10
3-way valve
System 18 - 24
1
Primary heat exchanger
2
Safety valve
3
Heating flow
4
Heating return
5
Circulation pump (Central heating)
4.4
Operating principle
4.4.1.
Gas/air setting
The casing fitted to the boiler is also used as an air box. Air is sucked
in by the fan and gas injected into the venturi by the fan intake. The
fan rotation speed is set according to the settings parameters, the
thermal energy requirement and the temperatures measured by the
temperature sensors. The gas and air are mixed in the venturi. The
gas/air ratio ensures that the quantities of gas and air are adjusted to
each other. This provides optimum combustion on the entire output
range. The gas/air mixture is fed into the burner on top of the
exchanger.
T003393-D
5
6
7
8
1
2
3
4
10
9
T003807-A
3
4
1
2
5
4. Technical description
Baxi MainEco Combi and System 24 - 28 - 35 / 18 - 24
14
02092014 - 7619497-02