Parameter
Description
Unit
EHC-04
SCB04-B
DM001
Domestic Hot Water tank temperature (bottom sensor) °C
X
DM006
Domestic Hot Water tank temperature (top sensor)
X
DM009
Automatic/derogation status of Domestic Hot Water
mode:
0 =Scheduling
1 =Manual
2 =Antifrost
3 =Temporary
°C
X
DM029
Domestic Hot Water temperature setpoint
°C
X
HM001
Heat pump flow temperature after condenser
°C
X
HM002
Heat pump return temperature after condenser.
°C
X
HM033
Flow temperature setpoint in cooling mode
°C
X
HM034
Heat pump PCU backup flow temperature
°C
not used
HM035
Heat pump PCU backup return temperature
°C
not used
HM036
Heat pump PCU backup domestical hot water
temperature
°C
not used
HM037
Heat pump PCU back up Internal Setpoint
°C
not used
HM038
Heat pump PCU back up status
not used
HM039
Heat Pump PCU back up Sub Status
not used
HM040
Heat Pump PCU back up Output power
%
not used
HM041
Heat pump PCU back up locking code
not used
HM042
Heat pump PCU back up blocking code
not used
HM046
Heat pump 5V signal output setpoint
V
X
PM002
Central heating setpoint of the appliance
°C
X
Fxx.xx
Software version for the selected PCB
X
X
Pxx.xx
Parameter version for the selected PCB
X
X
Tab.28 Values available (X) in the
sub-menu
Parameter
Description
EHC--04
SCB04-B
F02.01
HMI software version
X
X
P00.01
HMI parameter version
X
X
7.1
Control system sequence
Tab.29 List of statuses and sub-statuses
Status Appliance: AM012 parameter
Appliance sub status: AM014 parameter
0
00= total system shut-down
1= heating / cooling / domestic hot water de
mand
Heat Demand
00 = off
The set point is reached. The compressor can start up whenever necessary.
01= anti-short cycle
The heating set point has been reached. The compressor is not authorised to
restart.
02= reversal valve switch to heating position
03= power supply to the hybrid pump
04= pending start-up conditions on the heat pump and the back-ups
62= three-way valve switch to domestic hot water position
7 Reading out measured values