Product name
iMPI V200
AWHP 4.5 MR
iMPI V200
AWHP 6 MR-3
iMPI V200
AWHP 8 MR-2
Brine-to-water heat pump
No
No
No
Low-temperature heat pump
No
No
No
Equipped with a supplementary heater
Yes
Yes
Yes
Heat pump combination heater
Yes
Yes
Yes
Rated heat output under average conditions
(1)
Prated
kW
4
4
6
Rated heat output under colder conditions
Prated
kW
5
4
6
Rated heat output under warmer conditions
Prated
kW
4
5
6
Declared capacity for heating for part load at an in
door temperature of 20 °C and outdoor temperature
T
j
T
j
= -7 °C
Pdh
kW
3.8
3.5
5.6
T
j
= +2 °C
Pdh
kW
4.3
4.5
2.9
T
j
= +7 °C
Pdh
kW
4.5
4.8
6.4
T
j
= +12 °C
Pdh
kW
5.5
5.2
4.3
T
j
= bivalent temperature
Pdh
kW
3.9
3.6
5.2
T
j
= operation limit temperature
Pdh
kW
3.9
3.6
5.2
Bivalent temperature
T
biv
°C
-10
-10
-10
Degradation coefficient
(2)
Cdh
—
1.0
1.0
1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
134
137
129
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
109
116
119
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
179
172
169
Declared coefficient of performance or primary en
ergy ratio for part load at an indoor temperature of
20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
-
1.64
1.89
1.95
T
j
= +2 °C
COPd
-
3.46
3.53
3.22
T
j
= +7 °C
COPd
-
4.96
4.74
4.57
T
j
= +12 °C
COPd
-
7.90
7.08
6.55
T
j
= bivalent temperature
COPd
-
1.20
1.52
1.70
T
j
= operation limit temperature
COPd
-
1.20
1.52
1.70
Operation limit temperature for air-to-water heat
pumps
TOL
°C
-10
-10
-10
Heating water operating limit temperature
WTOL
°C
55
60
60
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.049
0.049
Stand-by
P
SB
kW
0.009
0.015
0.014
Crankcase heater mode
P
CK
kW
0.000
0.055
0.055
Supplementary heater
Rated heat output
Psup
kW
0.0
0.0
0.0
Type of energy input
Electricity
Electricity
Electricity
Other specifications
Capacity control
Variable
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
49 – 61
49–65
49 – 67
Annual energy consumption under average con
ditions
Q
HE
kWh
2353
2124
3499
Annual energy consumption under colder condi
tions
Q
HE
kWh
4483
3721
4621
3 Technical specifications
7700954 - v03 - 13082018
iMPI V200
15
Содержание iMPI/E V200 11-16
Страница 56: ...13 Appendix 56 iMPI V200 7700954 v03 13082018 ...
Страница 57: ...13 Appendix 7700954 v03 13082018 iMPI V200 57 ...
Страница 58: ...13 Appendix 58 iMPI V200 7700954 v03 13082018 ...
Страница 60: ...7700954 v03 13082018 7700954 001 03 ...