Measurement type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Absorbed electrical pow
er
kWe
0.90
1.38
1.82
2.45
2.45
3.47
3.47
Nominal water flow rate
(ΔT = 5K)
m
3
/h
0.80
1.00
1.36
1.96
1.96
2.53
2.53
Tab.3
Heating mode: outside air tempe2 °C, water temperature at the 35 °C. Performances in accordance
with EN 14511-2.
Measurement type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Heat output
kW
3.47
3.74
6.80
10.19
10.19
12.90
12.90
Coefficient of Perform
ance (COP)
3.97
3.37
3.30
3.20
3.20
3.27
3.27
Absorbed electrical pow
er
kWe
0.88
1.11
2.06
3.19
3.19
3.94
3.94
Tab.4
Cooling mode: outside air tempe35 °C, water temperature at the 18 °C. Performances in accordance
with EN 14511-2.
Measurement type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Cooling output
kW
3.80
4.69
7.90
11.16
11.16
14.46
14.46
Energy efficiency ratio
(EER)
4.28
4.09
3.99
4.75
4.75
3.96
3.96
Absorbed electrical pow
er
kWe
0.89
1.15
2.00
2.35
2.35
3.65
3.65
Tab.5
Common specifications
Measurement type
Unit
AWHP 4.5
MR
AWHP 6
MR-3
AWHP 8
MR-2
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Total dynamic head at
nominal flow rate
kPa
65
63
44
25
25
—
—
Nominal air flow rate
m
3
/h
2680
2700
3300
6000
6000
6000
6000
Power voltage of the out
door unit
V
230
230
230
230
400
230
400
Start-up amperage
A
5
5
5
5
3
6
3
Maximal amperage
A
12
13
17
29.5
13
29.5
13
Acoustic power - Inner
side
(1)
dB(A)
49
49
49
48
48
48
48
Acoustic power - Outside dB(A)
61
65
67
69
69
70
70
Refrigerant fluid R410A
kg
1.3
1.4
3.2
4.6
4.6
4.6
4.6
R410A refrigerant
(2)
tCO
2
e
2.714
2.923
6.680
9.603
9.603
9.603
9.603
Refrigerant connection
(Liquid - Gas)
inch
1/4 - 1/2
1/4 - 1/2
3/8 - 5/8
3/8 - 5/8
3/8 - 5/8
3/8 - 5/8
3/8 - 5/8
Max. pre-charged length m
7
10
10
10
10
10
10
(1) Noise radiated by the enclosure - Test run in accordance with the NF EN 12102 standard, temperature conditions: air 7 °C, water 55 °C
(except for AWHP 4.5 MR: air 7 °C, water 45 °C inner and outer sides)
(2) The quantity of refrigerant in tonnes of CO
2
equivalent is calculated using the following formula: quantity (in kg) of refrigerant x GWP/
1000. The Global-Warming Potential (GWP) of R410A gas is 2088.
3 Technical specifications
7700954 - v03 - 13082018
iMPI V200
13