Parameter
Description
Factory setting
CIRCA
Factory setting
CIRCB
CP570
Time Program of the zone selected by the user
0 = programme 1
1 = programme 2
2 = programme 3
0
0
CP660
Choice icon to display this zone
0 =None
1 =All
2 =Bedroom
3 =Livingroom
4 =Study
5 =Outdoor
6 =Kitchen
7 =Basement
8 =Swimming pool
0
3
6.2.2
User \DHW menu
DP : Direct Hot Water Parameters = Domestic hot water tank parameters
Tab.16
Parameter
Description
Factory setting
DP060
Time program selected for DHW.
0 =Schedule 1
1 =Schedule 2
2 =Schedule 3
3 =Cooling
0
DP070
Comfort temperature setpoint from the Domestic Hot Water tank
Can be set from 40 °C to 65 °C
54
DP080
Reduced temperature setpoint from the Domestic Hot Water tank
Can be set from 10 °C to 60 °C
10
DP200
DHW primary mode current working setting
0 =Scheduling
1 =Manual
2 =Antifrost
3 =Temporary
1
DP337
Holiday temperature setpoint from the Domestic Hot Water tank
Can be set from 10 °C to 60 °C
10 °C
6.2.3
User \EHC–04 menu
AP : Appliance Parameters = Appliance parameters
Tab.17
Parameter
Description
Factory setting
AP015
Force manually the heat pump in cooling mode
0 =No
1 =Yes
0
AP016
Enable central heating heat demand processing
0= off (no heating or cooling)
1 = on
1
AP017
Enable domestic hot water heat demand processing
0 = off
1 = on
1
6 Settings
28
iMPI V200
7700954 - v03 - 13082018
Содержание iMPI/E V200 11-16
Страница 56: ...13 Appendix 56 iMPI V200 7700954 v03 13082018 ...
Страница 57: ...13 Appendix 7700954 v03 13082018 iMPI V200 57 ...
Страница 58: ...13 Appendix 58 iMPI V200 7700954 v03 13082018 ...
Страница 60: ...7700954 v03 13082018 7700954 001 03 ...