Product name
iMPI V200
AWHP 4.5 MR
iMPI V200
AWHP 6 MR-3
iMPI V200
AWHP 8 MR-2
Annual energy consumption under warmer condi
tions
Q
HE
kWh
1249
1492
1904
Rated air flow rate, outdoors for air-to-water heat
pumps
—
m
3
/h
2100
2100
3300
Declared load profile
L
L
L
Daily electricity consumption
Q
elec
kWh
4.020
4.816
4.816
Annual electricity consumption
AEC
kWh
845
968
968
Water heating energy efficiency
ƞ
wh
%
121.00
106.00
106.00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
0.000
Annual fuel consumption
AFC
GJ
0
0
0
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is
equal to the supplementary capacity for heating
sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
Tab.12 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
iMPI V200
AWHP 11 MR-2
AWHP 11 TR-2
iMPI V200
AWHP 16 MR-2
AWHP 16 TR-2
Air-to-water heat pump
Yes
Yes
Water-to-water heat pump
No
No
Brine-to-water heat pump
No
No
Low-temperature heat pump
No
No
Equipped with a supplementary heater
Yes
Yes
Heat pump combination heater
Yes
Yes
Rated heat output under average conditions
(1)
Prated
kW
6
9
Rated heat output under colder conditions
Prated
kW
4
7
Rated heat output under warmer conditions
Prated
kW
8
13
Declared capacity for heating for part load at an in
door temperature of 20 °C and outdoor tempera
ture
T
j
T
j
= -7 °C
Pdh
kW
5.9
9.0
T
j
= +2°C
Pdh
kW
5.3
6.5
T
j
= +7 °C
Pdh
kW
9.0
12.9
T
j
= +12 °C
Pdh
kW
7.7
10.0
T
j
= bivalent temperature
Pdh
kW
6.3
8.8
T
j
= operation limit temperature
Pdh
kW
6.3
8.8
Bivalent temperature
T
biv
°C
-10
-10
Degradation coefficient
(2)
Cdh
—
1.0
1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
125
121
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
113
113
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
167
161
Declared coefficient of performance or primary en
ergy ratio for part load at an indoor temperature of
20 °C and outdoor temperature
T
j
T
j
= -7 °C
COPd
-
1.87
1.85
T
j
= +2 °C
COPd
-
3.17
3.02
T
j
= +7 °C
COPd
-
4.54
4.34
T
j
= +12 °C
COPd
-
6.19
5.75
T
j
= bivalent temperature
COPd
-
1.20
1.35
3 Technical specifications
16
iMPI V200
7700954 - v03 - 13082018
Содержание iMPI/E V200 11-16
Страница 56: ...13 Appendix 56 iMPI V200 7700954 v03 13082018 ...
Страница 57: ...13 Appendix 7700954 v03 13082018 iMPI V200 57 ...
Страница 58: ...13 Appendix 58 iMPI V200 7700954 v03 13082018 ...
Страница 60: ...7700954 v03 13082018 7700954 001 03 ...