Product name
iMPI V200
AWHP 11 MR-2
AWHP 11 TR-2
iMPI V200
AWHP 16 MR-2
AWHP 16 TR-2
T
j
= operation limit temperature
COPd
-
1.20
1.35
Operation limit temperature for air-to-water heat
pumps
TOL
°C
-10
-10
Heating water operating limit temperature
WTOL
°C
60
60
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
Thermostat-off mode
P
TO
kW
0.023
0.035
Stand-by
P
SB
kW
0.023
0.023
Crankcase heater mode
P
CK
kW
0.055
0.055
Supplementary heater
Rated heat output
Psup
kW
0.0
0.0
Type of energy input
Electricity
Electricity
Other specifications
Capacity control
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
48–69
48 – 70
Annual energy consumption under average con
ditions
Q
HE
kWh
3999
5861
Annual energy consumption under colder condi
tions
Q
HE
kWh
3804
5684
Annual energy consumption under warmer condi
tions
Q
HE
kWh
2580
4120
Rated air flow rate, outdoors for air-to-water heat
pumps
—
m
3
/h
6000
6000
Declared load profile
L
L
Daily electricity consumption
Q
elec
kWh
4.816
4.816
Annual electricity consumption
AEC
kWh
968
968
Water heating energy efficiency
ƞ
wh
%
106.00
106.00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
Annual fuel consumption
AFC
GJ
0
0
(1) The rated heat output
Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplemen
tary heater
Psup is equal to the supplementary capacity for heating sup(Tj).
(2) If
Cdh is not determined by measurement, the default degradation coefficient is Cdh = 0.9.
See
The back cover for contact details.
3.2.5
Circulating pump
Important
The benchmark for the most efficient circulating pumps is EEI ≤
0.20.
3 Technical specifications