Installation
Manual Single Power Unit BUM64S/A/F
Document no.: 5.01056.03
51
6
figure 15: Safety relay X68
1)
Position see
*: Voltages that may appear at the terminals
**: Currents that may flow across the terminals
2)
Connection cross-section of conductor
A detailed description of the safety relay is to be found in
terminal
pos.
1)
description
U
interval
*
I
interval
**
A
2)
1
2
Feedback, if the
safety relay
is enabled (PELV)
0 V
(U
DC
)
or
24 V
(U
DC
)
0.01 A
(I
DC
)
to
5 A
(I
DC
)
1.5 mm
2
+24 V
3
+ 24 V- connection to disable
the safety relay (PELV)
0 V
(U
DC
)
to
24 V
(U
DC
)
0 mA
(I
DC
)
to
35 mA
(I
DC
)
1.5 mm
2
M 24 V
4
reference point to input
+ 24 V (PELV)
0 V
(U
DC
)
NOTE
When operating the motor, terminal 3 must be connected to +24 V (U
DC
) and terminal 4 must
be connected to 0 V (U
DC
).
„Safety relay OFF“ is saved as a message and must be reset by use of the controller.