Installation
Manual Single Power Unit BUM64S/A/F
Document no.: 5.01056.03
49
6
figure 13: Control terminal X99A
1)
Position, see
*: Voltages that may appear at the terminals
**: Currents that may flow across the terminals
2)
Conductor cross-section.
terminal
pos.
1)
description
U
interval
*
I
interval
**
A
2)
1
Message
"ready-for-use external"
(PELV)
Open contact:
supply unit not ready-for-use
Closed contact:
supply unit not ready-for-use
0 V (U
DC
)
to
24 V (U
DC
)
0 A (I
DC
)
to
0.5 A (I
DC
)
max.
2.5 mm
2
2
3
Message
"Warning"
(PELV)
Closed contact:
supply unit - no warning
Open contact:
supply unit - warning
4
+Reset
5
potential free optocoupler input for
reset of error messages (PELV)
PHASE ERR, POWER ERR, and BRAKE
OVERL.
figure 14: potential free optocoupler input
0 V (U
DC
)
or
24 V (U
DC
)
10 mA (I
DC
)
to
25 mA (I
DC
)
M Reset
6
Reference potential for +Reset input (PELV)
0 V
-