6.5
6.5.2.3 Safety relay X68
With the safety relay the drive can be switched to a torque-free state. This is achieved by
switching off +24 V at contacts 3 and 4.
WARNING
The following
may occur
,
if you do not observe this warning information:
m
serious personal injury
m
death
The hazard is:
mechanical influence
because of safety relay failure.
Take care, that contacts 1 and 2 are loaded by a minimum current of 10 mA while in service.
Operate the safety relay within its specifications.
Coil side
rated voltage
24 V (PELV)
operating voltage
19 V to 37 V at T
u
= 20 °C (PELV)
coil resistance
660
Ω
to 905
Ω
Contact side
switching voltage U
AC
max. 25 V
AC
(PELV)
switching voltage U
DC
max. 60 V (PELV)
switching current
max. 5 A
continuous current
min. 10 mA up to max. 6 A
switching capacity P
AC
max. 150 VA
switching capacity P
DC
max. 30 W