Safe Stop 2 (SS2)
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
Baumüller Nürnberg GmbH
64
10.5
10.5.1 Error reaction with function-specific SS1 time for the safety function "SS2" and its following
function "SOS"
With the software extension SAF-002/3 and with the SAF module configuration software
ProSafePara from version V1.1.0.0 for every safety function a function-specific SS1-time
can be parameterized:
Figure 23:
P212.005: SS1 time for the safety function „SS2“
This setting also applies to the following function SOS (an individual error can also occur
during the following function SOS).
This time always acts as a delay if an individual error occurs.
This is supposed to allow the drive to drive down a brake ramp before the STO is
activated.
During the "SS2" function and its following function "SOS" the following individual errors
can occur:
m
Switchover to a data set which was not set
m
There is no encoder connected
m
Encoder standstill time extended
m
Exceeding the tolerance window
If a value in P212.005 is parameterized greater than zero, STO is not immediately carried
out if an individual error occurs, but at first the parameterized time of this function is
processed. An automatic signalization to the controller is connected if the error occurs.
Thereby the drive error 1066 "SS1 stop forced by SAF module" is initiated.
An accordant error reaction can be parameterized in the controller (refer to
"Parameterization of the error reaction" and setting of "SS2 stop time" in
).
Example:
During the process of the following function "SOS" the individual error exceeds the
tolerance window. In
on page 63 this case is shown. The time "SS1" thereby
accords to the parameterized time set in P212.005 before "STO" is operated.