Safe Stop 1 (SS1)
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
Baumüller Nürnberg GmbH
60
10.4
10.4.1 Signalize SS1-start to the controller
With the software extension SAF-002/3 and with the SAF module configuration software
ProSafePara from version V1.1.0.0 due to the parameterization of P211.009 it is possible
to report the activation start of the SS1 function to the controller (refer to
page 59: "Signalize SS1-start to the controller"):
From FW 1.10 onwards the controller can be parameterized in such a way that it detects
this signal from the SAF module and the drive can now be driven precisely and
independently down a steep brake ramp. Thereby, in certain cases no higher level
controller is required.
By the immediate active braking to the standstill of the drive it is avoided that the drive
coasts to a stop.
In order to achieve an efficient solution the brake ramp of the controller must be set so
that the drive comes to a standstill before the SS1-time in the SAF-module is processed
and the "STO module is activated. The required setting of the controller are described in
the current parameter manual b maXX BM5000 ("SS1 stop", SS1 stop time" and error
reaction).
In ProSafePara the following parameters have to be set:
Setting SS1-time in the SAF module:
Figure 18:
Example: Axis 1 setting SS1 time
The ProSafePara parameter P211.009 of the accordant axis must be set to "On" so that
a signalization to the controller can be carried out:
Figure 19:
Example: Axis 1 activation of the signaling
Содержание BM5-O-SAF-002