Command processing
Drive status:
Not ready to start
(P108.006 := 0)
Checking by
whether safety function is active
(P201.012 == 7)
b maXX 5000,
YES
NO
Drive state:
(P108.006:=1),
release possible
Inhibited function
Erro message controller
(error number 2422)
Command processing
Trouble shooting
by safety module
No error
Error
Command processing
Entry in the
error log file
Error message
safety module
(P201.019)
red LED is on
Error message controller
(error number 1013)
Drive status:
Error
(P108.006 := 15)
Block C
Commissioning and replacement of the module
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
131
16
Figure 57:
Process of the module change procedure block C
Error number
Short description
2411
No valid safety parameter file on SAF module
2419
Module change from SAF-003 to SAF-002
2420
No valid controller for SAF-module
2422
No FSoE communication active at SAF-002 or SAF-003
2423
Pulse inhibit because of SAF-100
NOTE!
m
If the data sets on the Safety Module are
not identical
with the controller’s data,
a copy of the data set is made. Generally this copy is made from the controller in
direction of the Safety Module.
m
If a copy of the data set is necessary from the Safety Module to the controller, the
controller’s parameter record must be deleted with the reset-module before (see
Содержание BM5-O-SAF-002