Safe Field Bus Communication via FSoE
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
107
12
Coding of S_StatusWord1
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit
0
0
0
0
0
No error
0
0
0
0
1
STO
0
0
0
1
0
SS1
0
0
0
1
1
SS2
0
0
1
0
0
SOS
0
0
1
0
1
SLS
0
0
1
1
0
SDI
0
0
1
1
1
SBC
0
1
0
0
0
SLP
0
1
0
0
1
SLI
0
1
0
1
0
SLA
0
1
0
1
1
SSM
0
1
1
0
0
SCA
0
1
1
0
1
SLT
0
0
0
No error
0
0
1
Triggering caused by a
limit violation
0
1
0
Triggering caused by an
incorrect parameter set
0
1
1
Triggering caused by a
missing absolute position
1
0
0
Triggering caused by a
missing rotary encoder
1
0
1
Triggering caused by
time-out of the rotary
encoder
1
1
0
0
0
0
0
0
No FSoE connection
X
X
X
X
X
X
X
X
Specification for
S_ControlWord1
Bit 0 – 7
a)
NOTE!
At the standard version of "STO" bit 0 is not set, as there is neither a noncompliance
nor an error; bit 0 is set as an error reaction not before it is switched over to a STO
parameter set, which is not applied.
a)
This is a copy of S_ControlWord1 bit 0 - 7. It acts as a feedback, if the setting is acting and when it started to act.