Safe Operating Stop (SOS)
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
Baumüller Nürnberg GmbH
66
10.6
Figure 24:
Safety function SOS
During noncompliance with "SOS" after a parameterizable "SS1" time "STO" is initiated
WARNING!
If a drive is operated in the operating mode SOS and if an external torque is existent,
which is able to display a danger in case of an error (STO), then the drive must be
equipped with a mechanical brake.
Observe chapter
Safety notes for the Function STO (Safe Torque Off)
10.6.1 Error reaction with function-specific SS1 time for the safety function "SOS"
With the software extension SAF-002/3 and the SAF module configuration software
ProSafePara a function-specific SS1 time can be parameterized from version V1.1.0.0
onward for every safety function:
Figure 25:
P213.005: SS1 time for the safety function „SOS“