Troubleshooting and fault correction
Operation manual
b maXX
BM4100 (NWR)
Document no.: 5.04052.09
103
9
4138
Invalid value at set value parameter No. 11
adjustable Check the set values in relation to the permitted
value range
4139
Invalid value at set value parameter No. 12
adjustable
4140
Invalid value at set value parameter No. 13
adjustable
4141
Invalid value at set value parameter No. 14
adjustable
4142
Invalid value at set value parameter No. 15
adjustable
4143
Invalid value at set value parameter No. 16
adjustable
4144
Invalid value for set value period
adjustable
4145
Invalid value for actual value period
adjustable
4146
Incorrect value for cycle offset set values
adjustable
4147
Incorrect value for cycle offset actual values
adjustable
4148
BACI timeout at cyclic data
adjustable Check communication rate and set timeout P0839
4149
BACI timeout at service data
adjustable
4150
Check results in faulty checksum
IS
Restart by switching off and on
4151
Ramp-up timeout when waiting for the slave type or
when waiting for the resetting of config pending flag
adjustable
4152
Invalid data transfer structure type
adjustable Contact Baumüller Nürnberg GmbH
4153
Internal error: Incorrect BACI status
adjustable
4154
Access conflicts with slave at cyclic communication adjustable
4155
Error cyclic communication: Parameter value wrong adjustable Check the value of the transmitted parameter
4156
Error cyclic communication: Alive counter conflict
adjustable Check if option module and controller are synchro-
nous
4157
Cmd interface: Channel number wrong (0 or > 6)
adjustable Contact Baumüller Nürnberg GmbH
4158
Cmd interface: Selected channel not available
adjustable
4159
Cmd interface: Internal error - wrong pointer
adjustable
4160
Cmd interface: Internal error - wrong state
adjustable
4161
Cmd interface: Wrong package No.
adjustable
4162
Cmd interface: Wrong command No.
adjustable
4163
Cmd interface: Wrong state at package handling
adjustable
4164
Cmd interface: Timeout at command processing
adjustable
4165
Cmd interface: Wrong package length
adjustable
4166
Cmd interface: Descriptor not available
adjustable
4167
Cmd interface: Wrong package type
adjustable
4168
Cmd interface: Checksum error
adjustable
4169
Module identification: PCI error at reading
adjustable Check option module for correct operation
4170
Module identification: PCI error at writing
adjustable
4171
Module identification: General error at reading
adjustable
4172
Module identification: General error at writing
adjustable
4173
Internal error
adjustable Contact Baumüller Nürnberg GmbH
4174
Configuration cyclic services: Parameters are not
cyclic writable
adjustable Select another parameter
4175
Configuration cyclic services: Invalid parameter No. adjustable
4176
Wrong option module error code
adjustable Contact Baumüller Nürnberg GmbH
4177 to 8192
reserved
Error code
Meaning
Reaction
Troubleshooting
Содержание b maXX 4100 Series
Страница 21: ...Safety Operation manual b maXX BM4100 NWR Document no 5 04052 09 21 of 142 2 Figure 2 Signs and labels BM416X ...
Страница 126: ...Baumüller accessories Operation manual b maXX BM4100 NWR Document no 5 04052 09 Baumüller Nürnberg GmbH 126 of 142 11 7 ...
Страница 138: ...Operation manual b maXX BM4100 NWR Document no 5 04052 09 Baumüller Nürnberg GmbH 138 of 142 Table of figures ...
Страница 142: ...Operation manual b maXX BM4100 NWR Document no 5 04052 09 Baumüller Nürnberg GmbH 142 of 142 Notes ...
Страница 143: ......