Demands on the power supply
Operation manual
b maXX
BM4100 (NWR)
Document no.: 5.04052.09
Baumüller Nürnberg GmbH
62
7.3
7.3
Demands on the power supply
For all important data, see
Requirements to the energy supply / supply system
Minor deviations from requirements in the power supply can lead to malfunctioning of the
device. If the power supply deviates too much from the requirements, the device can be
destroyed.
The devices may only be operated in industrial networks.
The destruction of the device can cause personal injury.
7.4
Requirements to the connecting cables
h
Take into account IEC/EN 60204-1, Chapter 13 when selecting the cable.
h
The protective ground cross-section of the cable must be compliant with IEC/
EN 60204-1, Section 5.2, Tab. 1.
h
A fixed connection for the protective ground conductor is mandatorily specified for op-
eration of the device.
h
Use copper cable approved for a minimum of 60 °C (drives < 3 x 100 A) or 75 °C
(drives
≥
3 x 100 A), if comply with UL 508C.
For further details (e.g. maximum permitted length), see
7.5
Protection of the device and the cable
Fuses must be installed to protect this device and the cables against overload and pos-
sible damage/destruction through the electrical power supply. For data on the required
fuses, see
DANGER!
Risk of fatal injury from electrical current!
If the requirements for the power supply are not complied, the device can be dam-
aged or destroyed, thereby greatly endangering individuals.
Therefore:
m
Prior to installation, ensure that the demands for power supply have been fulfilled.
Содержание b maXX 4100 Series
Страница 21: ...Safety Operation manual b maXX BM4100 NWR Document no 5 04052 09 21 of 142 2 Figure 2 Signs and labels BM416X ...
Страница 126: ...Baumüller accessories Operation manual b maXX BM4100 NWR Document no 5 04052 09 Baumüller Nürnberg GmbH 126 of 142 11 7 ...
Страница 138: ...Operation manual b maXX BM4100 NWR Document no 5 04052 09 Baumüller Nürnberg GmbH 138 of 142 Table of figures ...
Страница 142: ...Operation manual b maXX BM4100 NWR Document no 5 04052 09 Baumüller Nürnberg GmbH 142 of 142 Notes ...
Страница 143: ......