Cabling
Operation manual
b maXX
BM4100 (NWR)
Document no.: 5.04052.09
Baumüller Nürnberg GmbH
112
11.1
11.1 Cabling
11.1.1 Cables power supply-device
1)
Possible cross section
Use a shielded Baumüller cable, optical shield overlap > 85 %.
For UL conform machines/installation you must use UL certified circuit cables.
2)
Device
Cross section
1)
Connection to the device
BM41
35
4 x 6 mm
2
to
4 x 16 mm
2
flexible cable with wire end ferrule (screw terminal)
BM41
45
4 x 16 mm
2
to
4 x 50 mm
2
BM41
63
4 x 25 mm
2
to
4 x 150 mm
2
cable lug max. width 35 mm
current bar
2)
Connection lugs (current bars). Position see
Screw maximum two cable lugs to the current bar - one on the front side, one on the
reverse side of the bar.