ULTRASAMPLER® sample collection system
185
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
A straight piece of milk pipe (length
3 x NW) serves as a flow-calming
section upstream of the flow level meter.
The flow-calming section can extend out of the refrigerated sample
collection box.
There are four holes in the base plate of the bottle drive for connection
with the sample collection box.
Note:
•
When calculating the dimensions of the refrigerated sample collec-
tion box, take due account of the choice of sampler and the installation
options.
•
Allow for the possible use of a flow level meter with "vertical" instal-
lation position (installed horizontally in Fig. 2 and Fig. 3).
Fitting the milk pipeline
The branch pipe of the sampler and the flow level meter are integrated in
the milk pipeline in the sample collection box.
Duly allowing for the space required by the sampler and bottle drive, the milk
pipeline must be disconnected at the place designated for the branch pipe
and flow level meter (or must be assembled from individual pipe sections).
The exact position and length of the disconnection must be decided when
the sample collection box is being designed.
A connecting flange (standard part) of the corresponding width must be
welded onto both ends of the milk pipe at the disconnection point.
If the milk pipeline is fitted outside the sample collection box, there must be
axial clearance for the installation and removal of the sampler and flow level
meter when it has been released. The aim is to install the sampler firmly in
the sample collection box in a vibration-free location.
26.9.2
Installation of the ULTRASAMPLER
units
Installation of sampler type 6871-3/4/5
The sampler and branch pipe can be installed and removed either as two
separate units or as one unit screwed together.
Installation of branch pipe:
Fit sealing rings on the flanges of the branch pipe.
Mount the branch pipe on the milk pipeline by the flanges on both sides
(if using the flow level meter mount this on the flange on the
corresponding side). Tighten fasteners slightly.
Turn branch pipe until welded socket is horizontal. Tighten fasteners.
Содержание MAK TIGER 3003
Страница 13: ...Safety precautions 5 Measuring System MAK TIGER 3003 Service manual SA 131128 10 03 2020...
Страница 31: ...Measuring system MAK TIGER 3003 23 Measuring System MAK TIGER 3003 Service manual SA 131128 10 03 2020...
Страница 32: ...Measuring system MAK TIGER 3003 24 Measuring System MAK TIGER 3003 Service manual SA 131128 10 03 2020...
Страница 187: ...ULTRASAMPLER sample collection system 179 Measuring System MAK TIGER 3003 Service manual SA 131128 10 03 2020 Dimensions...
Страница 216: ...Measuring System MAK TIGER 3003 Service manual SA 131128 10 03 2020...