![Baroness SP160EB Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/baroness/sp160eb/sp160eb_owners-operating-manual_4023255024.webp)
A
Capacity
Inspection of Battery
Danger
Danger
Keep fire away while inspecting or charging
the battery.
The battery may explode.
Danger
Danger
Do not allow the battery fluid level to become
lower than the minimum level.
The battery may explode if it is used or
charged while the battery plate is exposed.
Make sure that the battery fluid level is
between the (maximum level) and the
(minimum level).
3
2
1
A
B
22x5d6-001
Inspection of Battery_001
1
Battery case
2
Purified water filling port
3
Battery plates
A
Maximum level 2 - 5 mm (0.079 -
0.197 in.)
B
Minimum level 10 mm (0.394 in.)
Inspection of Battery Cable
Warning
Loose or corroding terminals may result in an
insufficient charge, burnt terminal connectors,
or the battery catching fire or exploding.
Make sure that there is no abnormality such
as corrosion of the terminals and cables.
If there is corrosion in the terminals, brush it
off, and then lightly apply grease.
Make sure that the terminal nuts are not
loose.
If they are loose, firmly tighten the nuts.
1.
2.
Measuring Battery Specific Weight
Danger
Danger
Be careful not to let your skin, eyes or clothes,
etc., come into contact with the battery fluid
and not to swallow the fluid accidentally.
Should your skin or clothes come into contact
with the battery fluid, immediately wash them
with water.
Danger
Danger
When measuring the specific weight, wear
protective garments, safety glasses and
gloves, etc.
Measure the specific weight to determine the
battery condition.
Stand the outside cylinder of the
hydrometer vertically, and draw up the
battery fluid with the dropper.
Make sure that there are no bubbles on the
float when it is floating, and then look
horizontally at the scale to read the value in
contact with the top surface of the fluid.
A
2
1
48yhlu-007
Measuring Battery Specific Weight_001
1
Scale
2
Float
A
Reading the hydrometer
Note:
The specific weight is affected by
temperature. Convert the hydrometer
reading to the specific weight at 20 °C.
Correct specific weight = Hydrometer
r 0.0007 × (Temperature when
measured
-
20)
The remaining capacity of the battery is
approximately 100% when the specific
weight is 1.28.
1.
2.
1.
2.
・
SP160EB