Manual 2100-603
Page
5 of 44
MODEL
Rated
Volts &
Phase
No.
Field
Power
Circuits
Single Circuit
Dual Circuit
Minimum
Circuit
Ampacity
Maximum
External
Fuse or
Ckt. Brkr.
Field
Power
Wire
Size
Ground
Wire
Minimum
Circuit
Ampacity
Maximum
External Fuse
or Ckt. Breaker
Field Power
Wire Size
Ground
Wire Size
Ckt. A Ckt. B
Ckt. A Ckt. B
Ckt. A Ckt. B
Ckt. A Ckt. B
Q24H2DA0Z
A05
A10
230/208-1
1
1
1 or 2
22
47
72
30
50
80
10
8
4
10
10
8
22
50
30
50
10
8
10
10
Q24H2DB0Z
B06
B09
230/208-3
1
1
1
17
35
44
20
35
45
12
8
8
12
10
10
Q24H2DC0Z
C06
C09
460-3
1
1
1
10
19
23
15
20
25
14
12
10
14
12
10
Q30H2DA0Z
A05
A10
230/208-1
1
1
1 or 2
25
50
75
35
50
80
8
8
4
10
10
8
25
50
30
50
10
8
10
10
Q30H2DB0Z
B06
B09
B12
230/208-3
1
1
1
1
18
37
45
55
25
40
45
60
10
8
8
6
10
10
10
10
Q30H2DC0Z
C06
C09
C12
460-3
1
1
1
1
12
21
25
30
15
25
25
30
14
10
10
10
14
10
10
10
Q36H2DA0Z
A05
A10
A15
230/208-1
1
1
1 or 2
1 or 2
31
56
81
83
45
60
90
90
8
6
4
4
10
10
8
8
31
33
50
50
45
45
50
50
8
8
8
8
10
10
10
10
Q36H2DB0Z
B06
B09
B15
230/208-3
1
1
1
1
25
43
52
53
30
50
60
60
10
8
6
6
10
10
10
10
Q36H2DC0Z
C06
C09
C15
460-3
1
1
1
1
12
21
26
27
15
25
30
30
14
10
10
10
14
10
10
10
Q42H2DA0Z
A05
A10
A15
230/208-1
1
1
1 or 2
1 or 2
34
59
84
84
50
60
90
90
8
6
4
4
10
10
8
8
34
34
50
50
45
45
50
50
8
8
8
8
10
10
10
10
Q42H2DB0Z
B06
B09
B15
230/208-3
1
1
1
1
25
43
52
53
35
50
60
60
8
8
6
6
10
10
10
10
Q42H2DC0Z
C06
C09
C15
460-3
1
1
1
1
13
22
26
27
15
25
30
30
14
10
10
10
14
10
10
10
Q48H2DA0Z
A05
A10
A15
230/208-1
1
1 or 2
1 or 2
1 or 2
38
63
88
88
50
70
90
90
8
6
3
3
10
8
8
8
38
38
38
25
50
50
50
50
50
25
50
50
8
8
8
10
8
8
10
10
10
10
10
10
Q48H2DB0Z
B06
B09
B15
230/208-3
1
1
1
1
29
47
56
56
40
50
60
60
8
8
6
6
10
10
10
10
Q48H2DC0Z
C06
C09
C15
460-3
1
1
1
1
15
24
28
28
20
25
30
30
12
10
10
10
12
10
10
10
Q60H2DA0Z
A05
A10
A15
230/208-1
1
1 or 2
1 or 2
1 or 2
45
70
95
95
60
90
100
100
8
4
3
3
10
8
8
8
45
45
45
25
50
50
60
60
60
25
50
50
8
8
8
10
8
8
10
10
10
10
10
10
Q60H2DB0Z
B09
B15
230/208-3
1
1
1
31
58
58
45
60
60
8
6
6
10
10
10
Q60H2DC0Z
C09
C15
460-3
1
1
1
17
31
31
25
35
35
10
8
8
10
10
10
Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.
Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest
revision), article 310 for power conductor sizing.
CAUTION:
When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to
Note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three conductors are in a raceway.
Maximum KW that can operate with heat pump on is 10KW. Other 5KW energizes during emergency heating only.
Maximum KW that can operate with heat pump on is 9KW. Other 6KW energizes during emergency heating only.
NOTE:
Reference Form 7960-582 for dehumidification model performance information.
TABLE 2 — ELECTRICAL SPECIFICATIONS
Содержание Q-TEC Q24H2D Series
Страница 6: ...Manual 2100 603 Page 6 of 44 FIGURE 1 UNIT DIMENSIONS Q24H2D Q60H2D Q30H2D Q36H2D Q42H2D Q48H2D...
Страница 9: ...Manual 2100 603 Page 9 of 44 FIGURE 6 DUCTED APPLICATION FIGURE 5 INSTALLATION WITH DUCT FREE PLENUM...
Страница 13: ...Manual 2100 603 Page 13 of 44 MIS 2469 DRAIN BOX WALL SLEEVE OVERFLOW TUBE CAULK AROUND TUBE FIGURE 12A...
Страница 15: ...Manual 2100 603 Page 15 of 44 REMOVE KNOCK OUT FOR INDOOR DRAIN HOSE CONNECTOR MIS 2471 FIGURE 12C If Used...
Страница 31: ...Manual 2100 603 Page 31 of 44 FIGURE 22 FRESH AIR DAMPER REMOVAL MOUNTING SCREW...