3. Components of the Green BCM Solution
Depending on the overall configuration (number of displays, with/without OPS (Open pluggable specification
“Mini-PC” to be plugged into the display), number and type of power units) the design of the Power Module
19inch provides redundancy on SMPS failure, cf.
The Power Module 19inch is completed by the Green BCM Box and the Green ONOFF button.
Connecting the Power Module 19inch to the power net needs to be done by a qualified
electrician, cf.
4.2.3 Cabling within the responsibility of a qualified electrician
The manufacturer assumes no liability for incorrect, inadequate, irresponsible or unsafe
assembly of systems.
Never push objects of any kind into the power supply slots as they may touch dangerous voltage points or
short out parts that could result in a risk of fire or electrical shock.
3.4.1
Position and function of controls
PGM interface
This interface is used for servicing only!
DC connectors
The back plane features 6 exits (connection to the displays), labeled DC1 to DC6; each of them is safeguarded
with a fuse (F1 to F6).
CTRL IN, CTRL OUT
The CONTROL OUT interface of the Green BCM Box is connected to the CONTROL IN interface of the first Power
Module 19inch.
The CONTROL OUT interface of the first Power Module 19inch. is connected to the CONTROL IN interface of the
following Power Module 19inch.
Always connect the CONTROL OUT interface of the previous Power Module 19inch. to the CONTROL IN interface of
the following Power Module 19inch.
A shortening plug needs to be plugged into CONTROL OUT interface of the last Power Module 19inch.