7. Technical specifications
7.6
Module configurations
For countries with 100-110V power net, only the 800W version is available!
The 1200W version is restricted to countries with 220-240V power net!
Depending on the overall configuration (number of displays, with/without OPS (Open pluggable specification
“Mini-PC” to be plugged into the display), number and type of power units) the design of the Power Module
19inch provides redundancy on SMPS failure. Since power consumption is not only dependent on the number of
displays but also on the length of the cable, the following tables also includes the cable length.
Without redundancy
800 W power bricks 1200 W power bricks
1
2
3
4
1
2
3
4
110V
HVD5521
KVD5521
IVD5521
10 m
2
4
6
20 m
2
4
6
50 m
1
3
5
6
100 m
1
3
5
6
230V
HVD5521
KVD5521
IVD5521
10 m
2
4
6
3
6
20 m
2
4
6
3
5
6
50 m
1
3
5
6
2
5
6
100 m
1
3
5
6
2
5
6
Short explanation:
With power net 100-110V, the 1200 W power brick is not allowed (red)
The max. number of displays (green) depends on the cable length: in case of 10m cables, you can run 2 displays
with 1 power brick 800W. If you go for 100m cable, 1 power brick 800W serves for 1 display only – both, in case
of 100-110V and in case of 220-240V.
In case it is a 220-240V power net and you use the 1200W power brick, one power module runs 3 displays at
max. cable length of 20m.
With redundancy
In case you go for redundancy on the power bricks, the table looks like this. The “+1” is the redundant power
brick.
800 W power bricks
1200 W power bricks
1+1
2+1
3+1
1+1
2+1
3+1
110V
HVD5521
KVD5521
IVD5521
10 m
2
4
6
20 m
2
4
6
50 m
1
3
5
100 m
1
3
5
230V
HVD5521
KVD5521
IVD5521
10 m
2
4
6
3
6
20 m
2
4
6
3
5
6
50 m
1
3
5
2
5
6
100 m
1
3
5
2
5
6
Barco – Green BCM Solution – R591346 – user's manual – Revision 04– November-2016
____________________________________________________________________
49