4. Installation
4.2.1
Control cabling
The control lines are set up using 6wire cable (6P6C)
and RJ25 connectors.
The Green ONOFF button is connected to the CONTROL IN interface of the Green BCM Box.
The CONTROL OUT interface of the Green BCM Box is connected to the CONTROL IN interface of the first Power
Module 19inch.
The CONTROL OUT interface of the first Power Module 19inch. is connected to the CONTROL IN interface of the
following Power Module 19inch.
Always connect the CONTROL OUT interface of the previous Power Module 19inch. to the CONTROL IN interface of
the following Power Module 19inch.
A shortening plug needs to be plugged into CONTROL OUT interface of the last Power Module 19inch.
One Green BCM Box can control up to 50
displays.
One Green BCM peut contrôler jusqu'à 50
écrans.
Barco – Green BCM Solution – R591346 – user's manual – Revision 04– November-2016