4. Installation
Avoid sharp edges for the cable routing!
Position th primary wires or cabling so that
it cannot be pulled or contact hot surfaces.
It is recommended to apply an additional
strain relief!
Évitez les angles vifs pour l'acheminement
du câble!
Position ème fils primaires ou câblage de
sorte qu'il ne peut être tiré ou de contact
des surfaces chaudes.
Il est recommandé d'appliquer une
décharge de traction supplémentaire!
4.2.3.2
Connection of the displays via DC power cables
OVD, KVD and IVD displays with a DC power supply are connected to the Power Module 19inch via cables of 10m,
20m, 50m or 100m, respectively!
Only use cables supplied by Barco:
Z3472648 (10m), Z3472649(20m),
Z3472650 (50m) Z3472651(100m).
Other cables might violate local regulations
and MUST NOT be used!
Ne utilisez que des câbles fournis par Barco:
Z3472648 (10m), Z3472649 (20m),
Z3472650 (50m) Z3472651 (100m).
Autres câbles pourraient enfreindre les
règlements locaux et ne doit être utilisé!
The cables Z3472648/49/50/51 are designed for occasional flexible use and fixed installation subject to
normal mechanical load conditions. They are suitable for non-continuously recurring movement without
tensile load. Continuous operational movements, restricted guidance, usage of these cables in moving
cable carriers or on motor drum guidance or under a strain of more than 15 N/mm² are not allowed.
When guiding the cables please note that there are considerable thermal losses and therefore it is manda-
tory to care for appropriate distances between the cables and for proper ventilation.
Only use these cables when they are completely unwound! Operation is not allowed with wound up ca-
bles!
Please mind the min. bending radius and the allowed temperature range, see table below!
Mechanical and thermal properties:
Outer diameter
7.4 mm
Min. bending radius
Occasional flexing
15x outer diameter
Fixed installation
4x outer diameter
Temperature range
Occasional flexing
-15°C up to +70°C max. conductor temperature
Fixed installation
-40°C up to +75°C max. conductor temperature
Barco – Green BCM Solution – R591346 – user's manual – Revision 04– November-2016