5. Image menu
Select how to adjust the white point. There are two alternatives: temperature and coordinate.
Temperature
The white point is speci
fi
ed on a Kelvin scale between 3200K – 13000K tracking along the black body curve.
Coordinate
Coordinate: The white point is speci
fi
ed using an x,y coordinate in the CIE 1931 Chart.
Color mode
Image / Advanced / P7 RealColor —>Color Mode
Used to set the coordinates for color processing mode: RGB, RGBCMY, White.
RGB
Red, Green and Blue are moved according to the speci
fi
ed desired coordinates. Cyan, Magenta and Yellow
are calculated accordingly.
RGBCMY
Red, Green, Blue, Cyan, Magenta and Yellow are moved according to the speci
fi
ed desired coordinates.
White
White point only. No changes to RGBCMY. Default: White
Native
Native Colors. (Color Correction Off).
Native values
System Setting/ Service / Color —>Measured values
The current measured values (WRGB ) used for RealColor processing.
These values must be accurate for RealColor to perform correctly.
Current values are presented in the color gamut diagram. Measured values are represented by a solid line.
Default: values measured at the manufacturers facility.
Custom values
Image / Advanced / P7 RealColor —>Mode
Allows users to specifying red, green blue, cyan, magenta and yellow color coordinates (x,y) and gain.
Current values are presented in the color gamut diagram. Desired values are represented by a dotted line.
36
601–0442 BALDER 13/09/2017
Содержание Balder
Страница 1: ...Balder Installation Manual 601 0442 00 13 09 2017 ...
Страница 32: ...3 Physical Installation 28 601 0442 BALDER 13 09 2017 ...
Страница 44: ...6 Advanced picture adjustments 40 601 0442 BALDER 13 09 2017 ...
Страница 52: ...7 Installation menu 48 601 0442 BALDER 13 09 2017 ...
Страница 54: ...8 Status menu Lists the projector IP address 50 601 0442 BALDER 13 09 2017 ...