22
FW
FW2
HW
RW
SW
TW
mECHANICAL CONNECTION
Max power input
(1)
kW
CV
3,7÷7,7
5,0÷10,5
4,0÷10,5
5,4÷14,2
7,1÷11,5
9,7÷15,6
4,4÷11,6
6,0÷15,8
5,5÷7,5
10,8÷14,5
7,5÷20,5
10,2÷27,9
Max rotation speed
See following table
PUmP OIL
AGIP ROTRA MULTI THT
(2)
Quantity in weight
kg - lb
0,50 - 1,1 0,50 - 1,1 0,50 - 1,1
0,70 - 1,5
0,97 - 2,1 0,97 - 2,1
Quantity in volume
l - USgal
0,56 - 0,15 0,56 - 0,15 0,56 - 0,15 0,79 - 0,21 1,1 - 0,28 1,1 - 0,28
HYDRAULIC CONNECTION
Max water temperature
(3)
°C - °F
60 - 140
Min water temperature
°C - °F
5 - 41
Max water pressure
bar - psi
8 - 116
Max priming depth
m - ft
1 - 3,3 (1000, 1450 and 1750 RPM) 0,5 - 1,7 (2800 and 3400 RPM)
Min water flow rate
1,3 x max flow rate
PERFORmANCE - WEIGHT
Max flow rate
See following table
Max pressure
See following table
Max level of sound pressure -
uncertainty
79 dB(A)
1 dB(A)
Max weight
kg - lb
9,2 - 20,2 9,2 - 20,2 10,0 - 22,0 11,2 - 24,7 18,0 - 40,0 20,0 - 44,0
Specifications and details are approximate. The Manufacturer reserves the right to make all changes to the appliance deemed necessary.
(1)
Depending on specific model.
(2)
Corresponding oils:
U.T.T.O.
(Universal Tractor Trasmission Oil)
API GL-4
John Deere J20A
Massey-Ferguson M-1135
Ford M2C - 86 B
Esso Torque Fluid 62
Mobil Mobilfluid 422
Ford M2C - 134 B/C
Shell Donax TD
(3)
On request, models are available able to operate with water at a temperature of 85 °C/185 °F..
The third letter allows determining the top rotation speed, according to the following table:
Third letter
RPm
N
1000
Absent
1450
S
1750
R
2800
D
3400
For example: TWN 5636 (1000 RPM), LW 2020 (1450 RPM), HWD 4040 (3400 RPM).
A K, preceded by a dash (LW-K, ZW-K), means the pump features a built-in pressure unloader/regulation valve
(e.g.: LWR-K 2020, ZW-K 4022). This rule does not apply to the AX and BX models because these already
feature built-in pressure unloader/regulation valves.
The model code numbers allow determining max flow rate and pressure.
By means of the first two figures (if the number consists of four figures) or by means of the first three figures
(if the number consists of five figures) the max flow rate can be determined according to the following table:
Max flow rate in l/min = first two (or three) figures x 0.378
Max flow rate in USgpm = first two (or three) figures : 10
XXX
Содержание Comet AX Series
Страница 4: ...5 b a g c d e f b a b b h i n m l...