This manual consists of two distinct parts.

The first is intended for both the end user and the 

Skilled Technician

 and contains the pump operation and 

maintenance instructions; the second is dedicated to the 

Skilled Technician 

only and provides instructions 

for the correct integration of the pump in the end machine and for special maintenance.

By 

Skilled Technician

 is meant:

•  the Manufacturer of the machine (e.g., high pressure cleaner) in which the pump is integrated (from now 

on, when reference is made to “machine in which the pump is integrated”, this may also refer to “system in 

which the pump is integrated”, such as, for example, in the case of a pumping station);

•  a person, normally belonging to the after-sales centre, specifically trained and authorised to perform special 

maintenance jobs and repairs on the pump and on the machine in which this is integrated. It should be 

remembered that jobs on the electrical parts must be performed by a 

Skilled Technician

 who is also a 

Professional Electrician

, meaning a person professionally qualified and trained to check, install and repair 

electrical apparatus in a “workmanlike” manner and in accordance with the laws applicable in the country 

where the machine integrating the pump is installed.

PART ONE

GENERAL INFORmATION

Carefully read this manual and the manual of the machine in which the pump is integrated: 

always carefully 

comply with the instructions contained in them.

Special care must be given to reading the parts of the text marked by the symbol:

 WARNING

inasmuch as these contain important safety instructions concerning pump operation.

The Manufacturer disclaims all liability relating to damage caused by:

•  failure to abide by the contents of this manual and the manual of the machine in which the pump is integrated;

•  the pump being used in ways other than those indicated in the 

“I

NTENDED

 

USE

” 

paragraph;

•  the pump being used in ways contrary to applicable laws on safety and prevention of work accidents;

•  tampering with the safety devices and with max operating pressure limitation;

•  incorrect assembly and installation;

•  incorrect maintenance;

•  changes made or jobs done on the pump without the permission of the Manufacturer;

•  use of non-original spare parts or which are not suitable for the pump model;

•  repairs not performed by a 

Skilled Technician

.

USING AND LOOKING AFTER THE mANUAL

 WARNING

• This manual completes that of the machine in which the pump is integrated: 

read all the manuals carefully.

The manual must be deemed an integral part of the pump and must be looked after for future reference and 

kept in a protected place where it can easily be referred to in case of need.

Содержание Comet AX Series

Страница 1: ...HIGH PRESSURE PUMPS IT EN WARNING Read the instructions before using and assembling FR ES DE EN ASSEMBLY OPERATION AND MAINTENANCE INSTRUCTIONS USO E MANUTENZIONE...

Страница 2: ...11 5 9 5 10 13 2 12 HW 7 8 1 1 3 6 12 5 9 5 4 13 2 11 10 TW SW 7 8 1 1 3 6 5 9 5 4 13 2 12 10 18 LW ZW 7 8 1 3 11 6 12 2 13 10 4 5 15 14 9 1 5 RW 7 8 1 1 3 6 12 5 9 5 4 13 2 10 BW AW 5 8 1 3 11 6 12 2...

Страница 3: ...2 4 3 AX 8 1 3 6 5 13 2 11 4 9 7 20 10 14 15 19 12 BX 8 1 6 5 13 2 11 4 9 7 10 14 15 12 20 8 17 16 14 D A B C F E G H...

Страница 4: ...5 b a g c d e f b a b b h i n m l...

Страница 5: ...ine integrating the pump is installed Part ONE GENERAL INFORMATION Carefully read this manual and the manual of the machine in which the pump is integrated always carefully comply with the instruction...

Страница 6: ...e first two letters of the pump model code LW FW ZW etc allow identifying the specific model an exception is represented by the second series of FW pumps which is indicated by FW2 AX BX BW AW LW ZW ME...

Страница 7: ...d necessary 1 Depending on specific model 2 Corresponding oils U T T O Universal Tractor Trasmission Oil API GL 4 John Deere J20A Massey Ferguson M 1135 Ford M2C 86 B Esso Torque Fluid 62 Mobil Mobilf...

Страница 8: ...or a Skilled Technician to have it restored The identification plate 7 shows the serial number and the pump model by means of a specific code which permits identifying the main technical specificatio...

Страница 9: ...rd vehicles ships or planes contact the Manufacturer s Technical After Sales Service inasmuch as additional requirements may be necessary All other uses are to be deemed incorrect The Manufacturer dis...

Страница 10: ...lowthewatermainsconnectioninstructionsshowninthe Specifications and technical data paragraph with special reference to the priming depth and supply pressure and temperature in case of any doubts conta...

Страница 11: ...e During operation always keep an eye on the pump and the machine in which it is integrated and out of the reach of children in particular be very careful when using near nurseries clinics and old peo...

Страница 12: ...g individuals and the environment In particular never exceedthemaximumrecommendedconcentrationsandonlypreparethequantityofproductneededtoprevent it spreading on the ground and in waters Store the dete...

Страница 13: ...n elderlypeopleordisabledpersonswithoutsupervision to arrange them in a stable position without any risk of falling not to put them in contact or in the immediate vicinity of inflammable materials CLE...

Страница 14: ...ctivities paragraph Every 50 hours Check the integrity of the suction circuit Check and if necessary clean the suction filter Check the fastening of the pump to the motor to which it is coupled and or...

Страница 15: ...tionsinthe Specifications and technical data paragraph Suction circuit with choke points Check the suction circuit especially make sure the suction filter is clean Unsuitableconditionsofuse e g nozzle...

Страница 16: ...hichthepumpisintegrated and made available to the end user STANDARD FITTINGS Make sure the purchased product consists of the following elements pump oil cap with vent 8 pump manual declaration of inco...

Страница 17: ...rmly fastened either to the motor flange or on a stable base by means of the feet optional The pumps described in this manual depending on the model are available in versions for numerous applications...

Страница 18: ...and TW suction and delivery fittings are available both on the right side and on the left side of the head PRESSURE UNLOADER REGULATION VALVE In the models in which it is already built in pumps marked...

Страница 19: ...rscrews 9 6 6 9 6 6 9 6 6 4 3 0 f PTOflangescrews 9 6 6 9 6 6 9 6 6 25 18 4 g Plungernuts 6 4 4 6 4 4 6 4 4 10 7 4 Loctite243 h Eccentricshaftscrew 25 18 4 Loctite243 i Crankcasescrews 25 18 4 25 18 4...

Страница 20: ...A Via G Dorso 4 42124 Reggio Emilia ITALY Tel 39 0522 386111 E Mail Italia vendite comet re it fax 39 0522 386300 E Mail Export export comet re it fax 39 0522 386286 www comet re it 1610 0325 00A 02 2...

Отзывы: