background image

30

DISmANTLING AND DISPOSAL

Only qualified persons must be allowed to dismantle the pump and this operation must be performed in 

compliance with the laws applicable in the country where the machine in which it is integrated has been installed.

TROUbLESHOOTING

 WARNING

• Also follow the instructions contained in the manual of the machine in which the pump is integrated.

• Before doing any jobs, perform the operations described in the 

“s

top

 paragraph.

  In the event of not being able to restore the correct operation of the pump with the aid of the information 

contained on the following table, contact a 

Skilled Technician

.

PRObLEmS

CAUSES

REmEDIES

The pump does not 

prime.

Suction of air.

Check the integrity of the suction circuit.

Delivery line closed (e.g., spray gun closed).

Reset the delivery pressure (e.g., press the spray 

gun lever).

Suction circuit with choke points.

Check the suction circuit (especially make sure 

the suction filter is clean).

The pump fails to reach 

max pressure.

Pressure adjustment knob (15) not tightened 

enough.

Turn the knob clockwise until required pressure 

is achieved.

Not enough water supply or priming too deep. Make sure the water supply flow rate or priming 

depth is in compliance with the indications in the

 

“S

PECIFICATIONS

 

AND

 

TECHNICAL

 

DATA

 paragraph.

Suction circuit with choke points.

Check the suction circuit (especially make sure 

the suction filter is clean).

Unsuitable conditions of use (e.g., nozzle worn, 

lance in low-pressure position, etc.)

Restore the correct conditions of use.

Irregular pressure and 

flow rate (pulsating).

Air suction.

Check the integrity of the suction circuit.

Suction filter dirty.

Clean the filter.

Not enough water supply or priming too deep. Make sure the water supply flow rate or priming 

depth is in compliance with the indications in the

 

“S

PECIFICATIONS

 

AND

 

TECHNICAL

 

DATA

 paragraph.

The pump has not completed priming.

Prime the pump according to the indications 

of the 

“S

TANDARD

 O

PERATION

 (

HIGH

 

PRESSURE

)”

 

paragraph.

Accessory clogged (e.g. clogged nozzle).

Restore the correct use of the accessory.

Too much noise.

Suction circuit with choke points.

Check the suction circuit (especially make sure 

the suction filter is clean).

Water supply temperature too high.

Keep to the temperatures indicated in the 

“S

PECIFICATIONS

 

AND

 

TECHNICAL

 

DATA

 paragraph.

Low detergent suction. Use of the accessory not in low-pressure mode 

(e.g., lance not in low-pressure position).

Restore the correct use of the accessory.

Detergent metering device closed or set for 

low suction.

Turn the detergent adjustment knob (16) 

anticlockwise.

Use of detergent which is too viscous.

Keep to uses and dilutions shown on detergent 

plate.

Содержание Comet AX Series

Страница 1: ...HIGH PRESSURE PUMPS IT EN WARNING Read the instructions before using and assembling FR ES DE EN ASSEMBLY OPERATION AND MAINTENANCE INSTRUCTIONS USO E MANUTENZIONE...

Страница 2: ...11 5 9 5 10 13 2 12 HW 7 8 1 1 3 6 12 5 9 5 4 13 2 11 10 TW SW 7 8 1 1 3 6 5 9 5 4 13 2 12 10 18 LW ZW 7 8 1 3 11 6 12 2 13 10 4 5 15 14 9 1 5 RW 7 8 1 1 3 6 12 5 9 5 4 13 2 10 BW AW 5 8 1 3 11 6 12 2...

Страница 3: ...2 4 3 AX 8 1 3 6 5 13 2 11 4 9 7 20 10 14 15 19 12 BX 8 1 6 5 13 2 11 4 9 7 10 14 15 12 20 8 17 16 14 D A B C F E G H...

Страница 4: ...5 b a g c d e f b a b b h i n m l...

Страница 5: ...ine integrating the pump is installed Part ONE GENERAL INFORMATION Carefully read this manual and the manual of the machine in which the pump is integrated always carefully comply with the instruction...

Страница 6: ...e first two letters of the pump model code LW FW ZW etc allow identifying the specific model an exception is represented by the second series of FW pumps which is indicated by FW2 AX BX BW AW LW ZW ME...

Страница 7: ...d necessary 1 Depending on specific model 2 Corresponding oils U T T O Universal Tractor Trasmission Oil API GL 4 John Deere J20A Massey Ferguson M 1135 Ford M2C 86 B Esso Torque Fluid 62 Mobil Mobilf...

Страница 8: ...or a Skilled Technician to have it restored The identification plate 7 shows the serial number and the pump model by means of a specific code which permits identifying the main technical specificatio...

Страница 9: ...rd vehicles ships or planes contact the Manufacturer s Technical After Sales Service inasmuch as additional requirements may be necessary All other uses are to be deemed incorrect The Manufacturer dis...

Страница 10: ...lowthewatermainsconnectioninstructionsshowninthe Specifications and technical data paragraph with special reference to the priming depth and supply pressure and temperature in case of any doubts conta...

Страница 11: ...e During operation always keep an eye on the pump and the machine in which it is integrated and out of the reach of children in particular be very careful when using near nurseries clinics and old peo...

Страница 12: ...g individuals and the environment In particular never exceedthemaximumrecommendedconcentrationsandonlypreparethequantityofproductneededtoprevent it spreading on the ground and in waters Store the dete...

Страница 13: ...n elderlypeopleordisabledpersonswithoutsupervision to arrange them in a stable position without any risk of falling not to put them in contact or in the immediate vicinity of inflammable materials CLE...

Страница 14: ...ctivities paragraph Every 50 hours Check the integrity of the suction circuit Check and if necessary clean the suction filter Check the fastening of the pump to the motor to which it is coupled and or...

Страница 15: ...tionsinthe Specifications and technical data paragraph Suction circuit with choke points Check the suction circuit especially make sure the suction filter is clean Unsuitableconditionsofuse e g nozzle...

Страница 16: ...hichthepumpisintegrated and made available to the end user STANDARD FITTINGS Make sure the purchased product consists of the following elements pump oil cap with vent 8 pump manual declaration of inco...

Страница 17: ...rmly fastened either to the motor flange or on a stable base by means of the feet optional The pumps described in this manual depending on the model are available in versions for numerous applications...

Страница 18: ...and TW suction and delivery fittings are available both on the right side and on the left side of the head PRESSURE UNLOADER REGULATION VALVE In the models in which it is already built in pumps marked...

Страница 19: ...rscrews 9 6 6 9 6 6 9 6 6 4 3 0 f PTOflangescrews 9 6 6 9 6 6 9 6 6 25 18 4 g Plungernuts 6 4 4 6 4 4 6 4 4 10 7 4 Loctite243 h Eccentricshaftscrew 25 18 4 Loctite243 i Crankcasescrews 25 18 4 25 18 4...

Страница 20: ...A Via G Dorso 4 42124 Reggio Emilia ITALY Tel 39 0522 386111 E Mail Italia vendite comet re it fax 39 0522 386300 E Mail Export export comet re it fax 39 0522 386286 www comet re it 1610 0325 00A 02 2...

Отзывы: