 WARNING

• This part of the manual is dedicated to 

Skilled Technicians

 and is not intended for users of the machine in 

which the pump is integrated.

UNPACKING

 WARNING

• During unpacking, always wear gloves and protective eyewear, to prevent injuring hands and eyes.

• Some pumps are heavy components (also refer to the 

“s

peciFications

 

and

 

technical

 

data

” 

paragraph) and these 

are therefore best unpacked by cutting away the bottom of the cardboard box.

• The packaging elements (plastic bags, staples, etc.) must not be left within reach of children as they represent 

potential hazard sources.

• Packaging components must be disposed of according to the regulations in force in the country where the 

machine in which the pump is integrated has been manufactured.

   Plastic packaging must not be discarded in the environment.

• After unpacking the pump, make sure no parts are missing and that all parts are in perfect condition, and that 

the identification plate is in place and legible.

  In case of any doubt, do not install the pump, but contact the Manufacturer or a 

Skilled Technician

• This manual and the warranty certificate must always accompany the machine in which the pump is integrated 

and made available to the end user.

STANDARD FITTINGS

Make sure the purchased product consists of the following elements:

•  pump;

•  oil cap with vent (8);

•  pump manual;

•  declaration of incorporation;

•  warranty certificate.

In case of problems, contact the Manufacturer or a 

Skilled Technician

.

INSTALLATION

 WARNING

• The 

Skilled Technician

 must abide by the installation instructions contained in this manual, in particular, the 

specifications of the motor (electric or internal combustion), to be coupled to the pump must be in conformity 

with the constructive performance and specifications of the pump (power, rotation speed, flanging, etc.), as 

shown on the Manufacturer’s technical documentation.

• The machine in which the pump is integrated must be made in such a way as to ensure conformity with 

the safety requirements indicated in the European Directives. This fact is guaranteed by 

 markings and 

by the Declaration of Conformity of the Manufacturer of the machine in which the pump is integrated.

• The pump must be installed and allowed to operate horizontally (for any exceptions in merit, contact the 

Manufacturer).

• The pump must be stably fastened.

• Being of the positive-displacement type, the pump must always be equipped with a pressure unloader/regulation 

valve (such valve is already built in the pump marked by the letter K preceded by a dash and in the AX and BX 

series pumps).

EN

Содержание Comet AX Series

Страница 1: ...HIGH PRESSURE PUMPS IT EN WARNING Read the instructions before using and assembling FR ES DE EN ASSEMBLY OPERATION AND MAINTENANCE INSTRUCTIONS USO E MANUTENZIONE...

Страница 2: ...11 5 9 5 10 13 2 12 HW 7 8 1 1 3 6 12 5 9 5 4 13 2 11 10 TW SW 7 8 1 1 3 6 5 9 5 4 13 2 12 10 18 LW ZW 7 8 1 3 11 6 12 2 13 10 4 5 15 14 9 1 5 RW 7 8 1 1 3 6 12 5 9 5 4 13 2 10 BW AW 5 8 1 3 11 6 12 2...

Страница 3: ...2 4 3 AX 8 1 3 6 5 13 2 11 4 9 7 20 10 14 15 19 12 BX 8 1 6 5 13 2 11 4 9 7 10 14 15 12 20 8 17 16 14 D A B C F E G H...

Страница 4: ...5 b a g c d e f b a b b h i n m l...

Страница 5: ...ine integrating the pump is installed Part ONE GENERAL INFORMATION Carefully read this manual and the manual of the machine in which the pump is integrated always carefully comply with the instruction...

Страница 6: ...e first two letters of the pump model code LW FW ZW etc allow identifying the specific model an exception is represented by the second series of FW pumps which is indicated by FW2 AX BX BW AW LW ZW ME...

Страница 7: ...d necessary 1 Depending on specific model 2 Corresponding oils U T T O Universal Tractor Trasmission Oil API GL 4 John Deere J20A Massey Ferguson M 1135 Ford M2C 86 B Esso Torque Fluid 62 Mobil Mobilf...

Страница 8: ...or a Skilled Technician to have it restored The identification plate 7 shows the serial number and the pump model by means of a specific code which permits identifying the main technical specificatio...

Страница 9: ...rd vehicles ships or planes contact the Manufacturer s Technical After Sales Service inasmuch as additional requirements may be necessary All other uses are to be deemed incorrect The Manufacturer dis...

Страница 10: ...lowthewatermainsconnectioninstructionsshowninthe Specifications and technical data paragraph with special reference to the priming depth and supply pressure and temperature in case of any doubts conta...

Страница 11: ...e During operation always keep an eye on the pump and the machine in which it is integrated and out of the reach of children in particular be very careful when using near nurseries clinics and old peo...

Страница 12: ...g individuals and the environment In particular never exceedthemaximumrecommendedconcentrationsandonlypreparethequantityofproductneededtoprevent it spreading on the ground and in waters Store the dete...

Страница 13: ...n elderlypeopleordisabledpersonswithoutsupervision to arrange them in a stable position without any risk of falling not to put them in contact or in the immediate vicinity of inflammable materials CLE...

Страница 14: ...ctivities paragraph Every 50 hours Check the integrity of the suction circuit Check and if necessary clean the suction filter Check the fastening of the pump to the motor to which it is coupled and or...

Страница 15: ...tionsinthe Specifications and technical data paragraph Suction circuit with choke points Check the suction circuit especially make sure the suction filter is clean Unsuitableconditionsofuse e g nozzle...

Страница 16: ...hichthepumpisintegrated and made available to the end user STANDARD FITTINGS Make sure the purchased product consists of the following elements pump oil cap with vent 8 pump manual declaration of inco...

Страница 17: ...rmly fastened either to the motor flange or on a stable base by means of the feet optional The pumps described in this manual depending on the model are available in versions for numerous applications...

Страница 18: ...and TW suction and delivery fittings are available both on the right side and on the left side of the head PRESSURE UNLOADER REGULATION VALVE In the models in which it is already built in pumps marked...

Страница 19: ...rscrews 9 6 6 9 6 6 9 6 6 4 3 0 f PTOflangescrews 9 6 6 9 6 6 9 6 6 25 18 4 g Plungernuts 6 4 4 6 4 4 6 4 4 10 7 4 Loctite243 h Eccentricshaftscrew 25 18 4 Loctite243 i Crankcasescrews 25 18 4 25 18 4...

Страница 20: ...A Via G Dorso 4 42124 Reggio Emilia ITALY Tel 39 0522 386111 E Mail Italia vendite comet re it fax 39 0522 386300 E Mail Export export comet re it fax 39 0522 386286 www comet re it 1610 0325 00A 02 2...

Отзывы: