background image

33

HYDRAULIC CONNECTION

For the hydraulic suction, delivery and bypass connections, refer to the following table and to Fig. 4, which 

represents a generic diagram of a possible machine integrating the pump.

  A Pump
  b  Pressure unloader /regulation valve
  C  Suction circuit
  D  Delivery circuit
  E  Spray gun (example of accessory)
  F motor
  G Lance
  H  Nozzle head

CAUTION

• Follow the connection instructions already indicated in the 

“C

HECKING

 

AND

 

CONNECTING

 

UP

 

TO

 

THE

 

WATER

 

SUPPLY

 and 

“S

PECIFICATIONS

 

AND

 

TECHNICAL

 

DATA

 paragraphs.

  In particular, the suction circuit must be sized so as not to determine on the pump suction fitting:

- a pressure higher than 8 bar/116 psi;

- a vacuum higher than: 0,15 bar/2,18 psi (series AX, BX and pumps at 1000, 1450 and 1750 RPM); 

0,1 bar/1,45 psi (MTP LWR-K, MTP ZWR-K); 0,1 bar/1,45 psi (pumps at 2800 and 3400 RPM).

• At pump suction, a filter of adequate dimensions must be fitted. In case of doubts, contact the Manufacturer.

• The suction pipes must have a suitable internal diameter and a nominal pressure of 10 bar/145 psi.

• The delivery pipes must have a nominal pressure not below the pump max. pressure.

On the models LW, ZW, FW, RW, HW, AW, BW, SW and TW, suction and delivery fittings are available both 

on the right side and on the left side of the head.

PRESSURE UNLOADER/REGULATION vALvE

In the models in which it is already built-in (pumps marked with the letter K preceded by a dash and pumps 

of the AX and BX series), this is factory set so maximum pump pressure is achieved, using a nozzle which also 

allows having a small flow rate in bypass (at least 0.3-0.6 l/min/0.08-0.16 USgpm).

The Manufacturer’s Technical Assistance Service is at the disposal of the 

Skilled Technician

 to provide all the 

information needed, taking into account the fact that such adjustment may have to be corrected according to 

the plant engineering configuration in which the pump is installed.

RESETTING THE PRESSURE UNLOADER/REGULATION vALvE

 WARNING

• Operating pressure must never exceed the maximum value indicated for the pump (see also the 

s

peciFications

 

and

 

technical

 

data

” 

paragraph).

To reset the valve, proceed as follows (refer to Fig. 5):

-  remove the plastic knob by pulling it upwards;

-  loosen the Allen screw (m);

-  turn the retention ring nut (l) anticlockwise, so as to partially unscrew it;

-  set the required pressure by means of the hexagonal knob (n) (turn clockwise to increase the pressure, 

anticlockwise to reduce the pressure);

-  turn the retention ring nut (l) clockwise, to tighten it;

-  fully tighten the Allen screw (m).

EN

Содержание Comet AX Series

Страница 1: ...HIGH PRESSURE PUMPS IT EN WARNING Read the instructions before using and assembling FR ES DE EN ASSEMBLY OPERATION AND MAINTENANCE INSTRUCTIONS USO E MANUTENZIONE...

Страница 2: ...11 5 9 5 10 13 2 12 HW 7 8 1 1 3 6 12 5 9 5 4 13 2 11 10 TW SW 7 8 1 1 3 6 5 9 5 4 13 2 12 10 18 LW ZW 7 8 1 3 11 6 12 2 13 10 4 5 15 14 9 1 5 RW 7 8 1 1 3 6 12 5 9 5 4 13 2 10 BW AW 5 8 1 3 11 6 12 2...

Страница 3: ...2 4 3 AX 8 1 3 6 5 13 2 11 4 9 7 20 10 14 15 19 12 BX 8 1 6 5 13 2 11 4 9 7 10 14 15 12 20 8 17 16 14 D A B C F E G H...

Страница 4: ...5 b a g c d e f b a b b h i n m l...

Страница 5: ...ine integrating the pump is installed Part ONE GENERAL INFORMATION Carefully read this manual and the manual of the machine in which the pump is integrated always carefully comply with the instruction...

Страница 6: ...e first two letters of the pump model code LW FW ZW etc allow identifying the specific model an exception is represented by the second series of FW pumps which is indicated by FW2 AX BX BW AW LW ZW ME...

Страница 7: ...d necessary 1 Depending on specific model 2 Corresponding oils U T T O Universal Tractor Trasmission Oil API GL 4 John Deere J20A Massey Ferguson M 1135 Ford M2C 86 B Esso Torque Fluid 62 Mobil Mobilf...

Страница 8: ...or a Skilled Technician to have it restored The identification plate 7 shows the serial number and the pump model by means of a specific code which permits identifying the main technical specificatio...

Страница 9: ...rd vehicles ships or planes contact the Manufacturer s Technical After Sales Service inasmuch as additional requirements may be necessary All other uses are to be deemed incorrect The Manufacturer dis...

Страница 10: ...lowthewatermainsconnectioninstructionsshowninthe Specifications and technical data paragraph with special reference to the priming depth and supply pressure and temperature in case of any doubts conta...

Страница 11: ...e During operation always keep an eye on the pump and the machine in which it is integrated and out of the reach of children in particular be very careful when using near nurseries clinics and old peo...

Страница 12: ...g individuals and the environment In particular never exceedthemaximumrecommendedconcentrationsandonlypreparethequantityofproductneededtoprevent it spreading on the ground and in waters Store the dete...

Страница 13: ...n elderlypeopleordisabledpersonswithoutsupervision to arrange them in a stable position without any risk of falling not to put them in contact or in the immediate vicinity of inflammable materials CLE...

Страница 14: ...ctivities paragraph Every 50 hours Check the integrity of the suction circuit Check and if necessary clean the suction filter Check the fastening of the pump to the motor to which it is coupled and or...

Страница 15: ...tionsinthe Specifications and technical data paragraph Suction circuit with choke points Check the suction circuit especially make sure the suction filter is clean Unsuitableconditionsofuse e g nozzle...

Страница 16: ...hichthepumpisintegrated and made available to the end user STANDARD FITTINGS Make sure the purchased product consists of the following elements pump oil cap with vent 8 pump manual declaration of inco...

Страница 17: ...rmly fastened either to the motor flange or on a stable base by means of the feet optional The pumps described in this manual depending on the model are available in versions for numerous applications...

Страница 18: ...and TW suction and delivery fittings are available both on the right side and on the left side of the head PRESSURE UNLOADER REGULATION VALVE In the models in which it is already built in pumps marked...

Страница 19: ...rscrews 9 6 6 9 6 6 9 6 6 4 3 0 f PTOflangescrews 9 6 6 9 6 6 9 6 6 25 18 4 g Plungernuts 6 4 4 6 4 4 6 4 4 10 7 4 Loctite243 h Eccentricshaftscrew 25 18 4 Loctite243 i Crankcasescrews 25 18 4 25 18 4...

Страница 20: ...A Via G Dorso 4 42124 Reggio Emilia ITALY Tel 39 0522 386111 E Mail Italia vendite comet re it fax 39 0522 386300 E Mail Export export comet re it fax 39 0522 386286 www comet re it 1610 0325 00A 02 2...