21

The manual contains safety precautions for the operator and those surrounding him/her and for the protection 

of the environment.

In case of deterioration or loss, a new copy must be requested from the Manufacturer or from a 

Skilled 

Technician

.

In the event of the machine in which the pump is integrated being transferred to another user, please also 

include this manual.

The Manufacturer reserves the right to make all the amendments required to update and correct this publication 

without prior notice.

SYmbOLS

The symbol:

 

  

 WARNING

marking certain parts of the text indicates a likely chance of injury to persons unless the relative prescriptions 

and indications are followed.

The symbol:

 

  

CAUTION

marking certain parts of the text indicates the possibility of damaging the pump unless the relative instructions 

are followed.

SPECIFICATIONS AND TECHNICAL DATA

The first two letters of the pump model code (LW, FW, ZW, etc.) allow identifying the specific model (an 

exception is represented by the second series of FW pumps, which is indicated by FW2).

AX

bX

bW

AW

LW

ZW

mECHANICAL CONNECTION

Max power input

 (1)

kW

CV

0,3÷6,3

0,4÷8,6

0,54÷4,2

0,7÷5,7

2,0÷4,3

2,7÷5,8

4,7÷7,5

6,4÷10,2

0,2÷4,0

0,3÷5,4

3,7÷8,2

5,0÷11,1

Max rotation speed

See following table

PUmP OIL

AGIP ROTRA MULTI THT

 (2)

Quantity in weight

kg - lb

0,16 - 0,35 0,10 - 0,22 0,25 - 0,55 0,25 - 0,55 0,28 - 0,62 0,36 - 0,79

Quantity in volume

l - USgal

0,18 - 0,05 0,11 - 0,03 0,28 - 0,07 0,28 - 0,07 0,32 - 0,08 0,41 - 0,11

HYDRAULIC CONNECTION

Max water temperature

 (3)

°C - °F

60 - 140

Min water temperature

°C - °F

5 - 41

Max water pressure

bar - psi

8 - 116

Max priming depth

m - ft

1 - 3,3 (1000, 1450 and 1750 RPM)    0,5 - 1,7 (2800 and 3400 RPM)

Min water flow rate

1,3 x max flow rate

PERFORmANCE - WEIGHT

Max flow rate

See following table

Max pressure

See following table

Max level of sound pressure - 

uncertainty

79 dB(A)

1 dB(A)

Max weight

kg - lb

6,0 - 13,2 4,7 - 10,3 6,0 - 13,2

6,5 - 14,3

7,2 - 15,9 7,9 - 17,5

EN

Содержание Comet AX Series

Страница 1: ...HIGH PRESSURE PUMPS IT EN WARNING Read the instructions before using and assembling FR ES DE EN ASSEMBLY OPERATION AND MAINTENANCE INSTRUCTIONS USO E MANUTENZIONE...

Страница 2: ...11 5 9 5 10 13 2 12 HW 7 8 1 1 3 6 12 5 9 5 4 13 2 11 10 TW SW 7 8 1 1 3 6 5 9 5 4 13 2 12 10 18 LW ZW 7 8 1 3 11 6 12 2 13 10 4 5 15 14 9 1 5 RW 7 8 1 1 3 6 12 5 9 5 4 13 2 10 BW AW 5 8 1 3 11 6 12 2...

Страница 3: ...2 4 3 AX 8 1 3 6 5 13 2 11 4 9 7 20 10 14 15 19 12 BX 8 1 6 5 13 2 11 4 9 7 10 14 15 12 20 8 17 16 14 D A B C F E G H...

Страница 4: ...5 b a g c d e f b a b b h i n m l...

Страница 5: ...ine integrating the pump is installed Part ONE GENERAL INFORMATION Carefully read this manual and the manual of the machine in which the pump is integrated always carefully comply with the instruction...

Страница 6: ...e first two letters of the pump model code LW FW ZW etc allow identifying the specific model an exception is represented by the second series of FW pumps which is indicated by FW2 AX BX BW AW LW ZW ME...

Страница 7: ...d necessary 1 Depending on specific model 2 Corresponding oils U T T O Universal Tractor Trasmission Oil API GL 4 John Deere J20A Massey Ferguson M 1135 Ford M2C 86 B Esso Torque Fluid 62 Mobil Mobilf...

Страница 8: ...or a Skilled Technician to have it restored The identification plate 7 shows the serial number and the pump model by means of a specific code which permits identifying the main technical specificatio...

Страница 9: ...rd vehicles ships or planes contact the Manufacturer s Technical After Sales Service inasmuch as additional requirements may be necessary All other uses are to be deemed incorrect The Manufacturer dis...

Страница 10: ...lowthewatermainsconnectioninstructionsshowninthe Specifications and technical data paragraph with special reference to the priming depth and supply pressure and temperature in case of any doubts conta...

Страница 11: ...e During operation always keep an eye on the pump and the machine in which it is integrated and out of the reach of children in particular be very careful when using near nurseries clinics and old peo...

Страница 12: ...g individuals and the environment In particular never exceedthemaximumrecommendedconcentrationsandonlypreparethequantityofproductneededtoprevent it spreading on the ground and in waters Store the dete...

Страница 13: ...n elderlypeopleordisabledpersonswithoutsupervision to arrange them in a stable position without any risk of falling not to put them in contact or in the immediate vicinity of inflammable materials CLE...

Страница 14: ...ctivities paragraph Every 50 hours Check the integrity of the suction circuit Check and if necessary clean the suction filter Check the fastening of the pump to the motor to which it is coupled and or...

Страница 15: ...tionsinthe Specifications and technical data paragraph Suction circuit with choke points Check the suction circuit especially make sure the suction filter is clean Unsuitableconditionsofuse e g nozzle...

Страница 16: ...hichthepumpisintegrated and made available to the end user STANDARD FITTINGS Make sure the purchased product consists of the following elements pump oil cap with vent 8 pump manual declaration of inco...

Страница 17: ...rmly fastened either to the motor flange or on a stable base by means of the feet optional The pumps described in this manual depending on the model are available in versions for numerous applications...

Страница 18: ...and TW suction and delivery fittings are available both on the right side and on the left side of the head PRESSURE UNLOADER REGULATION VALVE In the models in which it is already built in pumps marked...

Страница 19: ...rscrews 9 6 6 9 6 6 9 6 6 4 3 0 f PTOflangescrews 9 6 6 9 6 6 9 6 6 25 18 4 g Plungernuts 6 4 4 6 4 4 6 4 4 10 7 4 Loctite243 h Eccentricshaftscrew 25 18 4 Loctite243 i Crankcasescrews 25 18 4 25 18 4...

Страница 20: ...A Via G Dorso 4 42124 Reggio Emilia ITALY Tel 39 0522 386111 E Mail Italia vendite comet re it fax 39 0522 386300 E Mail Export export comet re it fax 39 0522 386286 www comet re it 1610 0325 00A 02 2...