10.4 Universal (Input) Safety Modules
UM-FA-xA Safety Modules provide forced-guided, mechanically-linked relay (safety) outputs for the SX5 system when an
external manual reset (latch) is desired by the application. See datasheet p/n
Model
Description
UM-FA-9A
3 normally open (N.O.) redundant-output 6 amp contacts
UM-FA-11A
2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed (N.C.) auxiliary contact
10.5 Safety Controllers
Safety Controllers provide a fully configurable, software-based safety logic solution for monitoring safety and non-safety
devices. For additional models and XS26 expansion modules, see instruction manuals p/n
(SC22-3).
Non-Expandable Models Expandable Models
Description
SC26-2
XS26-2
26 convertible I/O and 2 Redundant Solid State Safety Outputs
SC26-2d
XS26-2d
26 convertible I/O and 2 Redundant Solid State Safety Outputs with Display
SC26-2e
XS26-2e
26 convertible I/O and 2 Redundant Solid State Safety Outputs with
Ethernet
SC26-2de
XS26-2de
26 convertible I/O and 2 Redundant Solid State Safety Outputs with Display
and Ethernet
Model
Description
SC22-3-S
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display
SC22-3-SU1
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display (includes
programming tool and USB cable)
SC22-3E-S
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display and Ethernet
SC22-3E-SU1
22 safety inputs, 10 Auxiliary Outputs, 3 Redundant Solid State safety Outputs with display and Ethernet
(includes programming tool and USB cable)
10.6 Interface Modules
IM-T-..A interface modules provide forced-guided, mechanically-linked relay (safety) outputs for the SX5 system with the
with Manual Reset function configured. The IM-T-..A interface module is required to be monitored by the EDM function
(performed by the reset line). See Banner datasheet p/n
Model
Description
IM-T-9A
Interface module, 3 normally open (N.O.) redundant-output 6 amp contacts
IM-T-11A
Interface module, 2 normally open (N.O.) redundant-output 6 amp contacts, plus 1 normally closed (N.C.) auxiliary
contact
SX5 Safety Laser Scanner