![Banner SX5 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/banner/sx5/sx5_instruction-manual_3759267057.webp)
Mute-Dependent Override function allows the user to manually force the OSSD outputs on for up to the configured
maximum override time (120 seconds). To initiate an override, the scanner's Safety Zone must be violated with the OSSD
outputs off and at least one mute device must be blocked (on). If this condition is true, the display shows the OVERRIDE
warning and the OSSD LED is green. The override function automatically terminates when one of the following happens:
• All the mute sensor inputs are de-actuated (switched to the off state) (in a bidirectional-muting configuration)
• The 120 second maximum override time limit has expired
• The override switch opens (is released)
• All the muting sensors are de-actuated and no beams of the Safety Zone are interrupted (in a unidirectional-muting
configuration)
The SX5's outputs stay on at the end of the override sequence (assuming the SX5's Safety Zone is clear, and it is
configured for Automatic Restart).
6.2.8 Muting Function T (X) (Bidirectional) or L (Unidirectional)
Selection
The SX5 has multiple muting configurations. The SX5 can monitor and respond to muting sensors in the Bidirectional or
Unidirectional configuration. Configure the directional setting of the muting on the Input Configuration screen.
Factory default setting: Bidirectional
Use the X configuration when the SX5 is mounted vertically and Bidirectional is selected in the configuration. The X
configuration uses two muting sensors (e.g. two pairs of opposed-mode photoelectric sensors as shown below). The
crossing point of the two sensing paths must be on the hazardous side of the Safety Zone.
M1
M2
D
D
Figure 42. Muting function in the X configuration
Use the T configuration when the SX5 is mounted vertically and Bidirectional is selected in the configuration. The T
configuration uses four muting sensors. For example, four pairs of opposed-mode or retro-reflective photoelectric sensors
or diffuse photoelectric sensors with background elimination, spaced with two on the inside and two on the outside of the
Safety Zone.
SX5 Safety Laser Scanner
www.bannerengineering.com - Tel: +1.763.544.3164
57